{
  "id": "holding-brewed-coffee",
  "url": "https://coffearium.org/entries/holding-brewed-coffee/",
  "license": "CC-BY-4.0",
  "title": "Holding brewed coffee",
  "summary": "What happens to brewed coffee kept hot on a hotplate or in an insulated jug – how it loses aroma, turns more acidic and cools – and what brewer standards, food-safety rules and burn research say about it.",
  "domain": "coffee-shops",
  "kind": "Concept",
  "stage": "cup",
  "topics": [
    "cafes",
    "science"
  ],
  "topicSections": {},
  "lang": "en",
  "status": "verified",
  "reviewer": "Coffearium verification pass",
  "lastVerified": "2026-11-20T00:00:00.000Z",
  "literatureSearched": "2026-11-20T00:00:00.000Z",
  "updated": "2026-11-20T00:00:00.000Z",
  "added": "2026-11-20T00:00:00.000Z",
  "brief": [
    "In a 2023 study, light and medium roasts held up to 3 h grew more sour as titratable acidity rose and pH fell; the dark roast grew more acidic without tasting more sour.<sup><a href=\"#src-s1\">1</a></sup>",
    "More sensory attributes decreased than increased during holding; the authors suggest that the loss of volatile aroma compounds may be the main concern.<sup><a href=\"#src-s1\">1</a></sup>",
    "Odour-active thiols, which carry the roasty, sulphury note, are lost quickly in warm coffee, partly by binding to melanoidins; a model study also links 2-furfurylthiol to the phenolic compound hydroxyhydroquinone.<sup><a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup>",
    "SCA 310-2021 requires a heated jug to keep home-brewed coffee at 80–85 °C for the first 30 min of holding.<sup><a href=\"#src-s9\">9</a></sup>",
    "The US Food Code 2026, a model code, sets hot holding at 57 °C or above for food that needs temperature control for safety.<sup><a href=\"#src-s11\">11</a></sup>"
  ],
  "quickFacts": [
    {
      "label": "Holding times studied",
      "value": "0–60 min on a hotplate (1989); 15 min to 3 h in three jug types (2023)"
    },
    {
      "label": "First sensory changes on a hotplate",
      "value": "Aroma after 45 min; acidity and bitterness after 60 min (1989)"
    },
    {
      "label": "Acidity over 3 h",
      "value": "Acidity up in all three roasts; sourness up in light and medium roasts only (2023)"
    },
    {
      "label": "2-Furfurylthiol, sealed brew at 40 °C",
      "value": "84% less available after 60 min (2019)"
    },
    {
      "label": "SCA 310-2021, heated jug",
      "value": "80–85 °C for the first 30 min; never above 85 °C from heating"
    },
    {
      "label": "EU switch-off (Regulation 2023/826)",
      "value": "≤5 min (insulated jug); ≤40 min (non-insulated jug)"
    },
    {
      "label": "Hot holding (food-safety rules)",
      "value": "US Food Code 2026, 57 °C or above; England (2013 Regulations), 63 °C"
    }
  ],
  "aka": [
    "Hot holding of coffee",
    "Keeping coffee warm"
  ],
  "linkTerms": [
    "holding brewed coffee",
    "hot holding",
    "holding time",
    "held coffee",
    "post-brew holding",
    "airpot"
  ],
  "related": [
    "filter-coffee-machines",
    "brew-methods",
    "serving-temperature",
    "acids-in-coffee",
    "chlorogenic-acids",
    "the-aroma-of-coffee",
    "melanoidins",
    "cafe-hygiene",
    "ready-to-drink-coffee",
    "cold-brew",
    "takeaway-cups-and-cafe-waste"
  ],
  "contested": [
    "Why held coffee turns more acidic: a 2022 study of stored ready-to-drink coffee cites the hydrolysis of chlorogenic acid lactones in coffee brew and found chlorogenic and quinic acids rising<sup><a href=\"#src-s5\">5</a></sup>; a 2007 study of freeze-dried coffee brew, rehydrated to a range of water activities and stored at −30 to 60 °C, suggests that mechanisms other than lactone hydrolysis, probably non-enzymatic browning, could contribute to the rise in acidity.<sup><a href=\"#src-s8\">8</a></sup> Neither study tested coffee held hot for service.",
    "Whether held coffee is liked less: a 1989 panel found significant changes in aroma after 45 min and in acidity and bitterness after 60 min on a hotplate<sup><a href=\"#src-s2\">2</a></sup>; in a 2023 study, 93 coffee professionals showed no preference for fresh (30 min) over held (180 min) coffee, although trained panels noticed changes.<sup><a href=\"#src-s1\">1</a></sup>"
  ],
  "corrections": [
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "The 2007 freeze-dried brew study is no longer counted among storage studies at 30 °C or below; the text gives its range of −30 to 60 °C for up to 10 months, and its suggestion is worded as mechanisms that could contribute to the rise in acidity.",
      "reason": "The abstract states storage from −30 to 60 °C and says other mechanisms could contribute, not that they replace lactone hydrolysis."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "The volatile-loss conclusion of the 2023 study and the thiol-binding statements are hedged as the sources state them: volatile loss may be the main concern; binding to phenolic compounds is limited to the hydroxyhydroquinone model system.",
      "reason": "The abstract says the primary concern may be the loss of volatile aroma compounds; the 2019 study tested hydroxyhydroquinone only as a potential conjugate in a model system."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "Sealed-vial wording changed from ‘the loss did not come from evaporation’ to ‘excluded losses into the headspace’; an open-vial result (volatilisation had a limited effect) added under open questions; table rows now say ‘available’ instead of ‘headspace’.",
      "reason": "The 2019 manuscript says the full-vial design excluded diffusion and headspace losses and reports ‘available’ 2-furfurylthiol."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "England: the two-hour rule is described as a defence for food not previously kept for service or display by the same person, and the scientific-assessment defence is added.",
      "reason": "Schedule 4 paragraph 7 sets defences, not a ‘once’ exception."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "Regulation (EU) 2023/826: the switch is to standby, off or a similar low-power condition; the regulation does not name keep-warm functions and lets machines offer user deactivation (Annex III 2(b)(5)); the regulation is no longer cited for insulated jugs adding no heat.",
      "reason": "Annex III points 2(b)(1), 2(b)(2) and 2(b)(5) as read on EUR-Lex."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "Burn section: the opening claim now quotes the 2019 review (served near brewing temperature, hotter than consumers prefer); ‘children are more vulnerable because’ and ‘most exposed’ were replaced by what the sources state; the 2017 temperature–injury point is marked as cited earlier work.",
      "reason": "The sources state skin thickness and the share of under-five scalds, not a causal vulnerability claim or a ranking of exposure."
    },
    {
      "date": "2026-11-20T00:00:00.000Z",
      "change": "Sun et al. 2019 quotes shortened so that none crosses a manuscript line number; IARC quote copied with curly quotation marks as printed.",
      "reason": "Quote rules: no quotes across line or page artefacts; character-for-character copying."
    }
  ],
  "sources": [
    {
      "id": "s1",
      "title": "The effect of post-brew holding time and carafe type on the sensory properties of drip brew coffee",
      "authors": "Batali, M. E.; Cotter, A. R.; Lim, L. X.; Ristenpart, W. D.; Guinard, J.-X.",
      "year": 2023,
      "publisher": "Journal of the Science of Food and Agriculture 103(8), 4095–4106",
      "url": "https://europepmc.org/article/MED/36524730",
      "doi": "10.1002/jsfa.12390",
      "tier": "A",
      "quote": "Sourness increased over time, consistent with acidity increasing over time (i.e., higher titratable acidity, lower pH), but only for the light and medium roasts.",
      "quotes": [
        {
          "text": "held in three different carafe types (glass on hot plate, thermal jacket, and vacuum insulated)",
          "for": "carafe types"
        },
        {
          "text": "for times ranging from 15 min to 3 h",
          "for": "holding times"
        },
        {
          "text": "Dark roasted coffee became significantly more acidic over 3 h post-brew",
          "for": "dark roast acidity"
        },
        {
          "text": "but was not perceived as more sour over time by the sensory panel",
          "for": "dark roast sourness"
        },
        {
          "text": "Surprisingly, the panel of coffee industry professionals showed no preference for fresh over held.",
          "for": "no preference"
        },
        {
          "text": "versus held (180 min) coffee for overall liking and attribute level adequacy",
          "for": "fresh versus held design"
        },
        {
          "text": "More sensory attributes decreased than increased over time",
          "for": "attributes decreased"
        },
        {
          "text": "may be the loss of volatile aroma compounds",
          "for": "volatile loss as main concern"
        },
        {
          "text": "sometimes as short as 30 min",
          "for": "retail discard times"
        },
        {
          "text": "Variations were observed between the thermal jacket and vacuum carafes for the light and dark roast",
          "for": "carafe differences"
        }
      ],
      "abstractOnly": true,
      "scope": {
        "claim": "finding",
        "context": "Lab, UC Davis (USA): drip brews of light, medium and dark roasts held 15 min to 3 h in glass-on-hotplate, thermal-jacket and vacuum-insulated carafes; trained panels and 93 professionals; abstract consulted, carafe temperatures not reported in it.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s2",
      "title": "Effect of holding-time on sensory quality of brewed coffee",
      "authors": "Feria-Morales, A. M.",
      "year": 1989,
      "publisher": "Food Quality and Preference 1(2), 87–89",
      "url": "https://www.sciencedirect.com/science/article/abs/pii/S0950329389800072",
      "doi": "10.1016/S0950-3293(89)80007-2",
      "tier": "A",
      "quote": "Statistically significant changes in the aroma attribute, Grassy/Green/Herbal were noted after as little as 45 minutes",
      "quotes": [
        {
          "text": "following standing on a hot-plate for 0, 15, 30, 45 and 60 minutes",
          "for": "design"
        },
        {
          "text": "taste attributes, Acidity and Bitterness were detected after 60 minutes holding-time.",
          "for": "changes after 60 min"
        }
      ],
      "abstractOnly": true,
      "scope": {
        "claim": "finding",
        "context": "Trained sensory panel (author at the International Coffee Organization, London); freshly brewed coffee on a hotplate for 0–60 min; abstract consulted, coffee and hotplate temperature not stated in it.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s3",
      "title": "Chemical interactions between odor-active thiols and melanoidins involved in the aroma staling of coffee beverages",
      "authors": "Hofmann, T.; Schieberle, P.",
      "year": 2002,
      "publisher": "Journal of Agricultural and Food Chemistry 50(2), 319–326",
      "url": "https://portal.fis.leibniz-lsb.tum.de/en/publications/chemical-interactions-between-odor-active-thiols-and-melanoidins--3/",
      "doi": "10.1021/jf010823n",
      "tier": "A",
      "quote": "confirmed the rapid loss of all thiols with increasing time while keeping the coffee brew warm in a thermos flask",
      "quotes": [
        {
          "text": "its concentration decreased by a factor of 16 upon addition of melanoidins",
          "for": "2-furfurylthiol and melanoidins"
        },
        {
          "text": "responsible for the decrease in the sulfury-roasty odor quality observed shortly after preparation of the coffee brew",
          "for": "loss of the sulphury-roasty note"
        }
      ],
      "abstractOnly": true,
      "scope": {
        "claim": "finding",
        "context": "Lab, Germany: coffee brew kept warm in a thermos flask, plus model systems with isolated melanoidins; abstract consulted, temperature and time of the flask test not stated in it.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s4",
      "title": "Aroma binding and stability in brewed coffee: A case study of 2-furfurylthiol",
      "authors": "Sun, Z.; Yang, N.; Liu, C.; Linforth, R. S. T.; Zhang, X.; Fisk, I. D.",
      "year": 2019,
      "publisher": "Food Chemistry 295, 449–455 (manuscript in the University of Nottingham repository)",
      "url": "https://nottingham-repository.worktribe.com/OutputFile/2291102",
      "doi": "10.1016/j.foodchem.2019.05.175",
      "tier": "A",
      "quote": "60 minutes, there was a substantial reduction in available 2-furfurylthiol (2-FFT) (84%),",
      "quotes": [
        {
          "text": "methanethiol (72%), 3-methyl-1H-pyrole (68%)",
          "for": "methanethiol 72%"
        },
        {
          "text": "(0, 15, 30, 45, 60 min) at 40 °C prior to solid-phase",
          "for": "storage at 40 °C"
        },
        {
          "text": "storage time on aroma, while excluding the effects of physical diffusion and losses into the",
          "for": "sealed, fully filled vials"
        },
        {
          "text": "It is proposed that 2-FFT was reduced through reversible chemical binding and",
          "for": "mechanism"
        },
        {
          "text": "demonstrating that a reversible binding reaction was the dominant mechanism of 2-FFT",
          "for": "reversible binding dominant"
        },
        {
          "text": "to protect 2-FFT from irreversible losses, while irreversible losses led to the reduction",
          "for": "irreversible loss"
        },
        {
          "text": "of total 2-FFT at low pH. A model reaction system was developed and a potential",
          "for": "at low pH; model system"
        },
        {
          "text": "conjugate, hydroxyhydroquinone, was reacted with 2-FFT.",
          "for": "hydroxyhydroquinone"
        },
        {
          "text": "a limited effect on 2-FFT loss compared to the predominant reversible binding in",
          "for": "open-vial test, volatilisation limited"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Lab, UK: robusta (Vietnam) French-press brew in fully filled, sealed vials held at 40 °C for up to 60 min; SPME-GC-MS; not a hot-holding temperature. Repository manuscript has line numbers; quotes kept within single lines.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s5",
      "title": "Identification of Non-Volatile Compounds Generated during Storage That Impact Flavor Stability of Ready-to-Drink Coffee",
      "authors": "Lin, H.; Tello, E.; Simons, C. T.; Peterson, D. G.",
      "year": 2022,
      "publisher": "Molecules 27(7), 2120",
      "url": "https://www.mdpi.com/1420-3049/27/7/2120",
      "doi": "10.3390/molecules27072120",
      "tier": "A",
      "quote": "A decrease in pH, rather than an increase in total acidity, was supported to impact the coffee flavor profile.",
      "quotes": [
        {
          "text": "MS chemical profiles for sixteen RTD coffee samples stored for 0, 1, 2, and 4 months at 30 °C",
          "for": "design"
        },
        {
          "text": "hydrolysis of the intramolecular ester bond in chlorogenic acid lactones has also been observed in the coffee brew",
          "for": "lactone hydrolysis (cited from earlier work)"
        },
        {
          "text": "Quinic acid showed the largest absolute concentration change by increasing 169 mg/L over 4 months",
          "for": "quinic acid rise"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Lab, USA: canned, retorted ready-to-drink coffee stored at 30 °C for up to 4 months; the lactone-hydrolysis statement is cited from earlier work.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s6",
      "title": "Identification of subthreshold chlorogenic acid lactones that contribute to flavor instability of ready-to-drink coffee",
      "authors": "Lin, H.; Tello, E.; Simons, C. T.; Peterson, D. G.",
      "year": 2022,
      "publisher": "Food Chemistry 395, 133555",
      "url": "https://www.sciencedirect.com/science/article/abs/pii/S0308814622015175",
      "doi": "10.1016/j.foodchem.2022.133555",
      "tier": "A",
      "quote": "The concentrations of eight CGLs significantly decreased in the coffee during the 4-month storage.",
      "quotes": [],
      "abstractOnly": true,
      "scope": {
        "claim": "finding",
        "context": "Lab, USA: ready-to-drink coffee stored for 4 months (30 °C per the article page); LC/MS and sensory recombination; abstract consulted.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s7",
      "title": "Effects of refrigeration and oxygen on the coffee brew composition",
      "authors": "Pérez-Martínez, M.; Sopelana, P.; de Peña, M. P.; Cid, C.",
      "year": 2008,
      "publisher": "European Food Research and Technology 227(6), 1633–1640 (author manuscript, University of Navarra, via CORE)",
      "url": "https://core.ac.uk/download/83583196.pdf",
      "doi": "10.1007/s00217-008-0887-x",
      "tier": "A",
      "tierNote": "Author manuscript of the peer-reviewed article; the same paper is cited in Ready-to-drink coffee with the publisher’s abstract page.",
      "quote": "pH decreases in all the coffee brews along the time, mainly in that stored at 25ºC with oxygen.",
      "quotes": [
        {
          "text": "A significant increase (p<0.05) of 5-CQA during the first 3 days of storage was observed for all coffee brews",
          "for": "5-CQA rise"
        },
        {
          "text": "These increases of caffeic acid might be originated by the hydrolysis of caffeoylquinic acids",
          "for": "caffeic acid"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Lab, Spain: Colombian arabica brew bottled in glass and stored at 4 and 25 °C, with and without oxygen, for 30–60 days; not hot holding.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s8",
      "title": "Modeling the effect of water activity and storage temperature on chemical stability of coffee brews",
      "authors": "Manzocco, L.; Nicoli, M. C.",
      "year": 2007,
      "publisher": "Journal of Agricultural and Food Chemistry 55(16), 6521–6526",
      "url": "https://air.uniud.it/handle/11390/880983",
      "doi": "10.1021/jf070166k",
      "tier": "A",
      "quote": "mechanisms other than lactones’ hydrolysis, probably related to nonenzymatic browning pathways",
      "quotes": [
        {
          "text": "the observed increase in acidity during coffee staling",
          "for": "acidity increase on staling"
        }
      ],
      "abstractOnly": true,
      "scope": {
        "claim": "hypothesis",
        "context": "Lab, Italy: freeze-dried coffee brew rehydrated to different water activities and stored at −30 to 60 °C for up to 10 months; acidity followed as H3O+ formation; the authors suggest other mechanisms could contribute; abstract consulted.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s9",
      "title": "SCA Standard 310-2021 Home Coffee Brewers: Specifications and Test Methods",
      "authors": "Specialty Coffee Association",
      "year": 2021,
      "publisher": "Specialty Coffee Association (document © 2022)",
      "url": "https://sca.coffee/s/SCA_Standard_310-2021.pdf",
      "tier": "A/B",
      "tierNote": "A for what the standard itself specifies (holding temperature, test procedure); B otherwise. It covers electrical filter brewers for home use.",
      "quote": "If heated, the holding receptacle shall maintain the temperature of the coffee in the range of 80 to 85°C",
      "quotes": [
        {
          "text": "during the first thirty (30) minutes of the holding time.",
          "for": "first 30 min"
        },
        {
          "text": "at no point should the temperature of the coffee increase above 85°C due to a heating element.",
          "for": "heated holding limit"
        },
        {
          "text": "Holding receptacle (carafe). The reservoir that receives the coffee after brewing.",
          "for": "definition of holding receptacle"
        },
        {
          "text": "The holding receptacle may be heated to keep the brew hot.",
          "for": "heated or unheated"
        },
        {
          "text": "measure the brew temperature in the holding receptacle every",
          "for": "test method, every minute for 30 min"
        },
        {
          "text": "designed for home use at atmospheric pressure.",
          "for": "scope"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "Certification specification and test methods for electrical filter brewers for home use (sections 6.6 and 7.7); requirements, not measurements.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s10",
      "title": "Commission Regulation (EU) 2023/826 of 17 April 2023 laying down ecodesign requirements for off mode, standby mode, and networked standby energy consumption of electrical and electronic household and office equipment pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulations (EC) No 1275/2008 and (EC) No 107/2009",
      "authors": "European Commission",
      "year": 2023,
      "publisher": "Official Journal of the European Union (text via EUR-Lex)",
      "url": "https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32023R0826",
      "tier": "A",
      "quote": "for drip filter household coffee machines storing the coffee in a non-insulated jug, a maximum of 40 minutes;",
      "quotes": [
        {
          "text": "for drip filter household coffee machines storing the coffee in an insulated jug, a maximum of five minutes;",
          "for": "insulated jug, 5 min"
        },
        {
          "text": "It shall apply from 9 May 2025.",
          "for": "date of application"
        },
        {
          "text": "The equipment may offer the user the option to deactivate the power management function.",
          "for": "user may deactivate power management"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "EU ecodesign regulation applying from 9 May 2025; Annex III points 2(b)(2) (coffee machine periods) and 2(b)(5) (user deactivation); no provision names keep-warm functions.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s11",
      "title": "Food Code 2026",
      "authors": "U.S. Food and Drug Administration (FDA); U.S. Public Health Service",
      "year": 2026,
      "publisher": "U.S. Food and Drug Administration",
      "url": "https://www.fda.gov/media/194741/download",
      "tier": "A",
      "tierNote": "Model code that state, local, tribal and territorial regulators use to write their own rules; it binds a business only where adopted.",
      "quote": "At 57°C (135°F) or above, except roasts cooked to a temperature and for",
      "quotes": [],
      "scope": {
        "claim": "guidance",
        "context": "US model food code for retail and food service, 2026 edition; section 3-501.16(A)(1), hot holding of time/temperature control for safety food. State adoption not checked.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s12",
      "title": "The Food Safety and Hygiene (England) Regulations 2013 (SI 2013/2996), Schedule 4: Temperature control requirements",
      "authors": "UK Government",
      "year": 2013,
      "publisher": "legislation.gov.uk (latest available revised version)",
      "url": "https://www.legislation.gov.uk/uksi/2013/2996/schedule/4",
      "tier": "A",
      "quote": "at a temperature below 63 °C any food which —",
      "quotes": [
        {
          "text": "needs to be kept at or above 63 °C in order to control the growth of pathogenic micro-organisms",
          "for": "condition for the rule (para. 6(c))"
        },
        {
          "text": "had been kept for service or on display for sale for a period of less than two hours; and",
          "for": "two-hour defence (para. 7(2)(a))"
        },
        {
          "text": "had not previously been kept for service or on display for sale by that person.",
          "for": "not previously kept for service (para. 7(2)(b))"
        },
        {
          "text": "a well-founded scientific assessment of the safety of the food at temperatures below 63 °C has concluded",
          "for": "scientific-assessment defence (para. 7(1))"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "Statutory instrument for England, Schedule 4 paragraphs 6 (offence) and 7 (defences) on hot holding; applies to cooked or reheated food for service or display that needs 63 °C to control pathogens or toxins.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s13",
      "title": "Regulation (EC) No 852/2004 of the European Parliament and of the Council of 29 April 2004 on the hygiene of foodstuffs (consolidated text)",
      "authors": "European Parliament; Council of the European Union",
      "year": 2021,
      "publisher": "Official Journal of the European Union, L 139, 30.4.2004; consolidated version of 24 March 2021",
      "url": "https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:02004R0852-20210324",
      "tier": "A",
      "quote": "are not to be kept at temperatures that might result in a risk to health",
      "quotes": [
        {
          "text": "limited periods outside temperature control are permitted, to accommodate the practicalities of handling",
          "for": "limited periods outside temperature control (Annex II, Ch. IX, 5)"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "EU food hygiene regulation, Annex II Chapter IX point 5; sets no numerical hot-holding temperature.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s14",
      "title": "A Review of Hot Beverage Temperatures – Satisfying Consumer Preference and Safety",
      "authors": "Abraham, J. P.; Diller, K. R.",
      "year": 2019,
      "publisher": "Journal of Food Science 84(8), 2011–2014",
      "url": "https://foodsci.oregonstate.edu/sites/agscid7/files/foodsci/attachments/hot-bev-temp.pdf",
      "doi": "10.1111/1750-3841.14699",
      "tier": "A",
      "quote": "It is estimated that a temperature decrease of 3 °C (5 °F) for large and insulated carafes but up to 20 °F for",
      "quotes": [
        {
          "text": "These estimates are based on multiple measurements made on commercially available brewing systems.",
          "for": "basis of the estimates"
        },
        {
          "text": "smaller, uninsulated glass carafes will occur during this process (Abraham et al., 2016).",
          "for": "small uninsulated glass carafes"
        },
        {
          "text": "At many establishments, hot beverages are held at elevated temperatures in containers or carafes that have an external heat source.",
          "for": "external heat source"
        },
        {
          "text": "far hotter than preferred by consumers.",
          "for": "served hotter than preferred"
        },
        {
          "text": "A simple means to reduce service temperature is to lower the holding temperature.",
          "for": "lower holding temperature"
        },
        {
          "text": "sufficiently high to cause immediate and serious risk for scald injuries",
          "for": "scald risk at brewing temperatures"
        },
        {
          "text": "the rate of injury increases very rapidly with each degree increase in the liquid temperature.",
          "for": "injury rate and temperature"
        },
        {
          "text": "spills which occur at higher temperatures (180 °F) are very likely to cause at least middermal burns",
          "for": "spills at 180 °F"
        },
        {
          "text": "temperatures in the range of 130 to 160 °F are recommended",
          "for": "proposed service range"
        },
        {
          "text": "The use of a cap approximately doubles the required cooling time.",
          "for": "lids"
        }
      ],
      "scope": {
        "claim": "description",
        "context": "Review of preference and scald studies for hot beverages; carafe values are estimates from measurements on commercial brewers, cited from Abraham et al. 2016.",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s15",
      "title": "Review of the initial treatment and avoidance of scald injuries",
      "authors": "Bourdon, R. T.; Nelson-Cheeseman, B. B.; Abraham, J. P.",
      "year": 2017,
      "publisher": "World Journal of Dermatology 6(2), 17–26",
      "url": "https://wjgnet.com/2218-6190/full/v6/i2/17.htm",
      "doi": "10.5314/wjd.v6.i2.17",
      "tier": "A",
      "quote": "beverage service temperatures, which are often in excess of 180 ℉ are at levels which have the potential to cause serious physical harm",
      "quotes": [
        {
          "text": "children (whose skin thickness is approximately 70% that of an adult)",
          "for": "children's skin"
        },
        {
          "text": "for small increases in exposure temperature, large changes in burn injury rates were observed.",
          "for": "burn rate and temperature (cited earlier work)"
        }
      ],
      "scope": {
        "claim": "description",
        "context": "Review of scald injuries from hot liquids, with tabulated cooling of beverages in a room at about 20 °C; the temperature–injury relation is cited from 1940s experiments (refs 11–14).",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s16",
      "title": "Patterns of burns and scalds in children",
      "authors": "Kemp, A. M.; Jones, S.; Lawson, Z.; Maguire, S. A.",
      "year": 2014,
      "publisher": "Archives of Disease in Childhood 99(4), 316–321",
      "url": "https://adc.bmj.com/content/archdischild/99/4/316.full.pdf",
      "doi": "10.1136/archdischild-2013-304991",
      "tier": "A",
      "quote": "Commonest scald agent (<5 years) was a cup/mug of hot beverage 55% (305/554)",
      "quotes": [
        {
          "text": "Prospective multicentred cross-sectional study of children (<16 years) with unintentional burns/scalds",
          "for": "design"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Prospective cross-sectional study of 1,215 children under 16 with unintentional burns or scalds at five emergency departments, a burns assessment unit and three regional children’s burns units (UK, Cardiff University).",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    },
    {
      "id": "s17",
      "title": "IARC Monographs evaluate drinking coffee, maté, and very hot beverages (Press release N° 244)",
      "authors": "International Agency for Research on Cancer",
      "year": 2016,
      "publisher": "International Agency for Research on Cancer (WHO), Lyon, 15 June 2016",
      "url": "https://www.iarc.who.int/wp-content/uploads/2018/07/pr244_E.pdf",
      "tier": "A",
      "quote": "Drinking very hot beverages was classified as probably carcinogenic to humans (Group 2A).",
      "quotes": [
        {
          "text": "“Very hot” refers to any beverages consumed at a temperature above 65 °C.",
          "for": "definition of very hot"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "Press release on the IARC Monographs evaluation, volume 116 (2016).",
        "checked": "2026-11-20T00:00:00.000Z"
      },
      "accessed": "2026-11-20T00:00:00.000Z"
    }
  ],
  "markdown": "## What happens after brewing\n\nCoffee is often brewed in batches and kept hot until it is poured. This is called holding, and the time it waits is the holding time.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s9\">9</a></sup> Coffee quality is believed to fall quickly after brewing. Some retail businesses discard unsold coffee after a set time, sometimes as short as 30 min.<sup><a href=\"#src-s1\">1</a></sup>\n\nThree things change while coffee waits. It loses aroma, it turns more acidic, and it cools unless something adds heat.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s14\">14</a></sup> How fast each happens depends on the vessel, the roast and the time.<sup><a href=\"#src-s1\">1</a></sup> Brewing itself is covered in Brew methods and filter coffee machines; this entry starts when the brew is finished.\n\n## Hotplates and insulated jugs\n\nThere are two basic ways to keep coffee hot. A heated vessel adds heat, for example a glass jug standing on a hotplate.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s9\">9</a></sup> An insulated vessel adds none; it only slows the loss of heat.<sup><a href=\"#src-s1\">1</a></sup> Insulated vessels include jugs with a thermal jacket and vacuum-insulated jugs or flasks.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s3\">3</a></sup>\n\nThe Specialty Coffee Association (SCA) calls the vessel that receives the brew the holding receptacle, or carafe. Its standard notes that this vessel may be heated to keep the brew hot.<sup><a href=\"#src-s9\">9</a></sup> Many businesses hold beverages in containers or carafes with an external heat source, according to a 2019 review.<sup><a href=\"#src-s14\">14</a></sup>\n\nSome heat is lost before holding even starts. The 2019 review, citing earlier work by its first author, estimates a loss of about 3 °C during brewing into large, insulated carafes.<sup><a href=\"#src-s14\">14</a></sup> Into small, uninsulated glass carafes it estimates up to 20 °F, about 11 °C (our conversion).<sup><a href=\"#src-s14\">14</a></sup> The review bases these estimates on measurements of commercial brewers.<sup><a href=\"#src-s14\">14</a></sup>\n\n## How flavour changes while coffee waits\n\nA 1989 study is one of the earliest on holding. A trained panel tasted freshly brewed coffee after 0, 15, 30, 45 and 60 min on a hotplate.<sup><a href=\"#src-s2\">2</a></sup> A green, grassy, herbal aroma changed significantly after 45 min. Acidity and bitterness changed after 60 min.<sup><a href=\"#src-s2\">2</a></sup>\n\nA 2023 study held light, medium and dark roasts for 15 min to 3 h. It used three jugs: glass on a hotplate, a thermal jacket and vacuum insulation.<sup><a href=\"#src-s1\">1</a></sup> Light and medium roasts tasted more sour over time.<sup><a href=\"#src-s1\">1</a></sup> The dark roast became more acidic by measurement, but the panel did not find it more sour.<sup><a href=\"#src-s1\">1</a></sup> More attributes became weaker than stronger. The authors suggest that losing volatile aroma compounds may be the main problem.<sup><a href=\"#src-s1\">1</a></sup>\n\nNoticeable is not the same as disliked. In the same study, 93 coffee professionals tasted coffee held 30 min and 180 min without knowing which was which. They showed no preference for the fresher coffee.<sup><a href=\"#src-s1\">1</a></sup>\n\n## Rules and recommendations\n\n**Brewer standard.** SCA 310-2021 covers electrical filter brewers for home use.<sup><a href=\"#src-s9\">9</a></sup> If the jug is heated, it must keep the coffee at 80–85 °C for the first 30 min.<sup><a href=\"#src-s9\">9</a></sup> The heating element must never raise the coffee above 85 °C.<sup><a href=\"#src-s9\">9</a></sup> The standard sets no limit on holding time beyond this 30-minute window.<sup><a href=\"#src-s9\">9</a></sup>\n\n**Switch-off rules in the EU.** Regulation (EU) 2023/826 applies from 9 May 2025.<sup><a href=\"#src-s10\">10</a></sup> Household drip filter machines with an insulated jug must switch automatically to standby, off or a similar low-power condition within 5 min. With a non-insulated jug, the limit is 40 min.<sup><a href=\"#src-s10\">10</a></sup> The regulation does not name keep-warm functions; a machine may let the user deactivate the power management, with a warning about the higher energy use.<sup><a href=\"#src-s10\">10</a></sup> The rule concerns energy use; filter coffee machines covers it in detail.\n\n**Food safety.** Hygiene law sets hot-holding temperatures for food that needs them for safety.<sup><a href=\"#src-s11\">11</a>,<a href=\"#src-s12\">12</a></sup> The US Food Code 2026 sets 57 °C or above.<sup><a href=\"#src-s11\">11</a></sup> In England, the 2013 regulations set 63 °C for food that must be kept hot to control pathogens.<sup><a href=\"#src-s12\">12</a></sup> Café hygiene covers these rules in general.\n\n<figure>\n<div data-figure=\"holding-brewed-coffee-times\"></div>\n<figcaption>Holding times in three studies and two rules, from the end of brewing: a hotplate panel (1989)<sup><a href=\"#src-s2\">2</a></sup>, three jug types (2023)<sup><a href=\"#src-s1\">1</a></sup>, sealed brew at 40 °C (2019)<sup><a href=\"#src-s4\">4</a></sup>, the 30-minute window of SCA 310-2021<sup><a href=\"#src-s9\">9</a></sup> and the EU switch-off delays.<sup><a href=\"#src-s10\">10</a></sup> The 2019 study did not hold coffee at serving temperature.</figcaption>\n</figure>\n\n## Holding heat and burns\n\nHot beverages are often served near their brewing temperature, far hotter than consumers prefer, according to a 2019 review.<sup><a href=\"#src-s14\">14</a></sup> Brewing temperatures are high enough to cause an immediate and serious risk of scalds, according to the 2019 review.<sup><a href=\"#src-s14\">14</a></sup> A 2017 review notes that service temperatures are often above 180 °F (about 82 °C).<sup><a href=\"#src-s15\">15</a></sup>\n\nYoung children are often scalded by hot drinks. In a multicentre study of children with burns and scalds, a cup or mug of hot drink caused 55% of scalds in those under five.<sup><a href=\"#src-s16\">16</a></sup> Preferred drinking temperatures, cooling in the cup and the cancer agency’s “very hot” threshold are covered in serving temperature.\n\n<!-- deep-dive -->\n\n## Reference values\n\nValues as the sources report them. “Held” means kept after brewing; storage studies at 40 °C or below are marked.\n\n| Parameter | Value reported | Conditions | Source |\n|---|---|---|---|\n| Holding times tested, hotplate | 0 · 15 · 30 · 45 · 60 min | Trained panel; freshly brewed coffee | Feria-Morales 1989<sup><a href=\"#src-s2\">2</a></sup> |\n| First significant aroma change | After 45 min (green, grassy, herbal) | Same study | Feria-Morales 1989<sup><a href=\"#src-s2\">2</a></sup> |\n| Change in acidity and bitterness | After 60 min | Same study | Feria-Morales 1989<sup><a href=\"#src-s2\">2</a></sup> |\n| Holding times tested, three jug types | 15 min to 3 h | Light, medium and dark roasts; glass on hotplate, thermal jacket, vacuum insulated | Batali et al. 2023<sup><a href=\"#src-s1\">1</a></sup> |\n| Titratable acidity and pH over 3 h | Acidity up, pH down | Sour taste rose in light and medium roasts only | Batali et al. 2023<sup><a href=\"#src-s1\">1</a></sup> |\n| Preference, fresh versus held | No preference | 93 professionals; 30 versus 180 min | Batali et al. 2023<sup><a href=\"#src-s1\">1</a></sup> |\n| Available 2-furfurylthiol | −84% in 60 min | Sealed robusta brew at 40 °C | Sun et al. 2019<sup><a href=\"#src-s4\">4</a></sup> |\n| Available methanethiol | −72% in 60 min | Same | Sun et al. 2019<sup><a href=\"#src-s4\">4</a></sup> |\n| 2-Furfurylthiol with melanoidins added | Decreased by a factor of 16 | Model system | Hofmann & Schieberle 2002<sup><a href=\"#src-s3\">3</a></sup> |\n| Quinic acid | +169 mg/L in 4 months | Ready-to-drink coffee at 30 °C | Lin et al. 2022<sup><a href=\"#src-s5\">5</a></sup> |\n| Chlorogenic acid lactones | Eight decreased significantly over 4 months | Ready-to-drink coffee | Lin et al. 2022<sup><a href=\"#src-s6\">6</a></sup> |\n| Heated jug, home brewers | 80–85 °C for the first 30 min; never above 85 °C from the heating element | Requirement | SCA 310-2021<sup><a href=\"#src-s9\">9</a></sup> |\n| Automatic switch to a low-power mode (EU) | ≤5 min insulated jug; ≤40 min non-insulated jug | Household drip filter machines, from 9 May 2025 | Regulation (EU) 2023/826<sup><a href=\"#src-s10\">10</a></sup> |\n| Hot holding (USA) | 57 °C or above (source: 135 °F) | Time/temperature control for safety food; model code | US Food Code 2026, 3-501.16(A)(1)<sup><a href=\"#src-s11\">11</a></sup> |\n| Hot holding (England) | 63 °C | Food that must be kept hot to control pathogens; defences in para. 7 | SI 2013/2996, Sch. 4<sup><a href=\"#src-s12\">12</a></sup> |\n| Hot holding (EU) | No number; not at temperatures that might result in a risk to health | Foods that support pathogens or toxins | Regulation (EC) 852/2004, Annex II, Ch. IX<sup><a href=\"#src-s13\">13</a></sup> |\n| Heat lost during brewing into the carafe | ≈3 °C (large, insulated); up to 20 °F, ≈11 °C (small, uninsulated glass) | Estimates from measurements on commercial brewers | Abraham & Diller 2019<sup><a href=\"#src-s14\">14</a></sup> |\n| Proposed service range | 130–160 °F (≈54–71 °C, our conversion) | Recommendation in a review | Abraham & Diller 2019<sup><a href=\"#src-s14\">14</a></sup> |\n| “Very hot” beverage (IARC) | Above 65 °C; drinking very hot beverages Group 2A | Classification, 2016 | IARC<sup><a href=\"#src-s17\">17</a></sup> |\n\n## Acids and pH during holding\n\nHeld coffee becomes more acidic. In the 2023 study, titratable acidity rose and pH fell over 3 h in light and medium roasts, and sourness rose with them.<sup><a href=\"#src-s1\">1</a></sup> The dark roast also became significantly more acidic, but the panel did not perceive it as more sour.<sup><a href=\"#src-s1\">1</a></sup> The abstract does not give the values or the jug temperatures.<sup><a href=\"#src-s1\">1</a></sup>\n\nThe usual explanation involves chlorogenic acid lactones. Roasting forms these bitter compounds from chlorogenic acids (see chlorogenic acids). A 2022 study of ready-to-drink coffee cites earlier work showing that their ester bond is hydrolysed in coffee brew.<sup><a href=\"#src-s5\">5</a></sup> In that study, stored at 30 °C for 4 months, chlorogenic acids and quinic acid rose; quinic acid rose by 169 mg/L.<sup><a href=\"#src-s5\">5</a></sup> A companion study found that eight lactones decreased significantly over the same storage.<sup><a href=\"#src-s6\">6</a></sup>\n\nThe first 2022 study concludes that the fall in pH, rather than a rise in total acidity, changed the flavour.<sup><a href=\"#src-s5\">5</a></sup> A 2008 study of brew bottled at 25 and 4 °C also found pH falling over time, fastest at 25 °C with oxygen.<sup><a href=\"#src-s7\">7</a></sup> In that study, 5-caffeoylquinic acid rose in the first 3 days. The authors suggest that rising caffeic acid came from the hydrolysis of caffeoylquinic acids.<sup><a href=\"#src-s7\">7</a></sup>\n\nNot every study points to lactones. A 2007 study of freeze-dried coffee brew, stored at a range of water activities, suggests that other pathways, probably non-enzymatic browning, could contribute to the rise in acidity.<sup><a href=\"#src-s8\">8</a></sup> The ready-to-drink and bottled-brew studies ran at 30 °C or below, for days to months; the freeze-dried brew was stored at −30 to 60 °C for up to 10 months.<sup><a href=\"#src-s5\">5</a>,<a href=\"#src-s7\">7</a>,<a href=\"#src-s8\">8</a></sup> No study consulted for this entry measured lactones, chlorogenic, quinic or caffeic acid in coffee held at 80–85 °C. How fast these reactions run at holding temperature is therefore not established here. Acids in coffee covers the acids themselves.\n\n## Aroma loss: thiols and volatiles\n\nThiols are sulphur compounds that give coffee its roasty, sulphury note. 2-Furfurylthiol is the best studied.<sup><a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup> A 2002 study confirmed the rapid loss of all thiols while coffee brew was kept warm in a vacuum flask.<sup><a href=\"#src-s3\">3</a></sup> Adding isolated melanoidins to the volatiles cut 2-furfurylthiol by a factor of 16.<sup><a href=\"#src-s3\">3</a></sup> The authors conclude that thiols binding to melanoidins explains the loss of the sulphury-roasty odour shortly after brewing.<sup><a href=\"#src-s3\">3</a></sup>\n\nA 2019 study followed a sealed robusta brew at 40 °C for 60 min. Available 2-furfurylthiol fell by 84% and methanethiol by 72%.<sup><a href=\"#src-s4\">4</a></sup> The vials were filled and sealed, which excluded losses into the headspace.<sup><a href=\"#src-s4\">4</a></sup> Reversible binding was the main route of 2-furfurylthiol loss; at low pH, irreversible losses reduced the total.<sup><a href=\"#src-s4\">4</a></sup> Hydroxyhydroquinone, a phenolic compound of roasted coffee, reacted with 2-furfurylthiol in a model system.<sup><a href=\"#src-s4\">4</a></sup>\n\nThese results fit the 2023 sensory study, where more attributes fell than rose during holding.<sup><a href=\"#src-s1\">1</a></sup> Its authors suggest that the loss of volatile aroma compounds may be the main concern.<sup><a href=\"#src-s1\">1</a></sup> No study consulted for this entry separated evaporation from chemical binding in a hotplate jug. The aroma compounds are described in the aroma of coffee and melanoidins.\n\n<figure>\n<div data-figure=\"holding-brewed-coffee-changes\"></div>\n<ol class=\"fig-legend\" aria-label=\"What changes in held coffee\">\n<li data-n=\"1\"><span><b>Heat in or heat kept.</b> A heated jug adds heat; an insulated jug only slows its loss.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s9\">9</a></sup></span></li>\n<li data-n=\"2\"><span><b>Thiols bound.</b> 2-Furfurylthiol and other thiols bind to melanoidins; in a model system, 2-furfurylthiol also reacted with the phenolic compound hydroxyhydroquinone; the roasty, sulphury note fades.<sup><a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup></span></li>\n<li data-n=\"3\"><span><b>Volatiles lost.</b> More sensory attributes weaken than strengthen; the loss of volatile aroma compounds is the main suspected cause.<sup><a href=\"#src-s1\">1</a></sup></span></li>\n<li data-n=\"4\"><span><b>Lactones hydrolysed.</b> Chlorogenic acid lactones decrease while chlorogenic and quinic acids rise; lactone hydrolysis is the explanation cited (shown in stored, not hot-held, coffee).<sup><a href=\"#src-s5\">5</a>,<a href=\"#src-s6\">6</a></sup></span></li>\n<li data-n=\"5\"><span><b>pH falls.</b> Titratable acidity rises and pH falls; light and medium roasts taste more sour.<sup><a href=\"#src-s1\">1</a></sup></span></li>\n</ol>\n<figcaption>What changes in brewed coffee while it is held, after the studies consulted for this entry. Step 4 is shown in coffee stored at 30 °C, not held hot. Schematic, not to scale.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a>,<a href=\"#src-s5\">5</a></sup></figcaption>\n</figure>\n\n## Jugs and temperature over time\n\nThe 2023 study found differences between the thermal-jacket and vacuum jugs for the light and dark roasts. For the medium roast, the type of jug made little difference.<sup><a href=\"#src-s1\">1</a></sup> The abstract does not report how the coffee temperature changed in each jug.<sup><a href=\"#src-s1\">1</a></sup>\n\nNo study consulted for this entry measured the temperature of coffee in a heated or insulated jug over several hours. The 2019 review gives estimates for the step into the carafe only: about 3 °C lost into large, insulated carafes and up to 20 °F into small glass ones.<sup><a href=\"#src-s14\">14</a></sup> SCA 310-2021 tests heated jugs by measuring the brew temperature every minute for 30 min, starting when the stream from the basket turns to drips.<sup><a href=\"#src-s9\">9</a></sup> How quickly a cup cools once poured is covered in serving temperature.\n\n## Food-safety rules on hot holding\n\nHot-holding rules are written for food in general, not for coffee. Each applies only in its own jurisdiction.\n\n- **United States (model code).** The FDA Food Code 2026 requires time/temperature control for safety food to be held at 57 °C (source: 135 °F) or above, section 3-501.16(A)(1).<sup><a href=\"#src-s11\">11</a></sup> The Food Code is a model; it binds a business only where a state or local authority has adopted it.<sup><a href=\"#src-s11\">11</a></sup>\n- **England.** Schedule 4 of the Food Safety and Hygiene (England) Regulations 2013 makes it an offence to keep food below 63 °C if it has been cooked or reheated, is for service or display, and needs 63 °C to control pathogens or toxins.<sup><a href=\"#src-s12\">12</a></sup> Defences include food kept for service or display for less than two hours that the same person had not kept for service before, and holding justified by a well-founded scientific assessment.<sup><a href=\"#src-s12\">12</a></sup>\n- **European Union.** Regulation (EC) 852/2004 gives no number. Foods that can support pathogens or toxins are not to be kept at temperatures that might result in a risk to health; limited periods outside temperature control are permitted.<sup><a href=\"#src-s13\">13</a></sup>\n\nNone of these hot-holding provisions names coffee. The sources consulted do not say whether an authority treats plain brewed coffee as food that needs hot holding for safety. Café hygiene covers holding rules, cold brew and milk.\n\n<figure>\n<div data-figure=\"holding-brewed-coffee-temperatures\"></div>\n<figcaption>Temperatures that frame holding: the SCA heated-jug band<sup><a href=\"#src-s9\">9</a></sup>, the service range proposed in a 2019 review (converted from °F)<sup><a href=\"#src-s14\">14</a></sup>, hot-holding limits in the US Food Code 2026 and in England<sup><a href=\"#src-s11\">11</a>,<a href=\"#src-s12\">12</a></sup>, the IARC “very hot” threshold<sup><a href=\"#src-s17\">17</a></sup> and the 40 °C test temperature of a 2019 aroma study.<sup><a href=\"#src-s4\">4</a></sup> The legal limits apply to food in general, not to coffee by name.</figcaption>\n</figure>\n\n## Holding temperature and scald risk\n\nA heated jug keeps coffee hot, and scald risk rises with temperature. The 2019 review states that the rate of injury rises very rapidly with each degree of liquid temperature.<sup><a href=\"#src-s14\">14</a></sup> Spills at 180 °F (about 82 °C) are very likely to cause at least mid-dermal burns, according to the same review.<sup><a href=\"#src-s14\">14</a></sup> A 2017 review on scald injuries cites earlier experiments in which small increases in temperature brought large changes in burn injury rates.<sup><a href=\"#src-s15\">15</a></sup>\n\nChildren’s skin is about 70% as thick as an adult’s, according to the 2017 review.<sup><a href=\"#src-s15\">15</a></sup> In the multicentre study of children under 16, hot drinks in a cup or mug were the commonest scald agent under five, at 305 of 554 scalds.<sup><a href=\"#src-s16\">16</a></sup> The 2019 review recommends serving at 130–160 °F (≈54–71 °C) and names a lower holding temperature as a simple way to reduce service temperature.<sup><a href=\"#src-s14\">14</a></sup> A lid roughly doubles the time a drink needs to cool.<sup><a href=\"#src-s14\">14</a></sup>\n\nThe SCA band for heated jugs, 80–85 °C, lies above the 65 °C that the International Agency for Research on Cancer (IARC) uses for “very hot” beverages.<sup><a href=\"#src-s9\">9</a>,<a href=\"#src-s17\">17</a></sup> The IARC threshold refers to the temperature at which a beverage is consumed, not held.<sup><a href=\"#src-s17\">17</a></sup> No authority consulted for this entry sets a maximum holding temperature for coffee.\n\n## Open questions\n\n- **Chemistry at holding temperature.** The studies of lactones and acids stored coffee at 30 °C or below for days to months.<sup><a href=\"#src-s5\">5</a>,<a href=\"#src-s6\">6</a>,<a href=\"#src-s7\">7</a></sup> No study consulted for this entry measured these compounds at 80–85 °C over minutes to hours.\n- **Temperature curves in jugs.** No source consulted for this entry reports measured coffee temperatures in heated or insulated jugs over several hours.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s14\">14</a></sup>\n- **Evaporation versus binding.** The aroma studies used a vacuum flask or vials at 40 °C.<sup><a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup> In open vials at 40 °C, the 2019 study found that volatilisation had a limited effect on 2-furfurylthiol loss compared with reversible binding.<sup><a href=\"#src-s4\">4</a></sup> How much aroma an open hotplate jug at holding temperature loses to the air, rather than to binding, has not been measured in the sources consulted here.\n- **Liking.** Trained panels detect changes within an hour, but professionals in one study did not prefer fresh coffee.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a></sup> Whether consumers react differently is not established in the sources consulted here.\n- **Discard times.** Retail discard times as short as 30 min are reported in one abstract, without a source for the practice.<sup><a href=\"#src-s1\">1</a></sup>\n\n## Key studies\n\n<div class=\"study\">\n<p><strong>Feria-Morales, 1989 – Holding time on a hotplate.</strong> A trained panel described freshly brewed coffee after 0–60 min on a hotplate, using 25 attributes. A green, grassy, herbal aroma changed significantly after 45 min, and acidity and bitterness changed after 60 min.</p>\n<p class=\"meta\">Food Quality and Preference 1(2), 87–89 · <a href=\"https://doi.org/10.1016/S0950-3293(89)80007-2\">doi:10.1016/S0950-3293(89)80007-2</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Batali et al., 2023 – Holding time and jug type.</strong> Light, medium and dark drip-brewed coffees were held for 15 min to 3 h in a glass jug on a hotplate, a thermal-jacket jug and a vacuum-insulated jug. Acidity rose in all roasts, but only the light and medium roasts tasted more sour; 93 professionals showed no preference for coffee held 30 min over coffee held 180 min.</p>\n<p class=\"meta\">Journal of the Science of Food and Agriculture 103(8), 4095–4106 · <a href=\"https://doi.org/10.1002/jsfa.12390\">doi:10.1002/jsfa.12390</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Hofmann & Schieberle, 2002 – Thiols and melanoidins.</strong> Coffee brew kept warm in a vacuum flask lost its odour-active thiols rapidly. Labelling and model studies showed that the thiols bind covalently to melanoidins, which the authors link to the fading of the roasty, sulphury note soon after brewing.</p>\n<p class=\"meta\">Journal of Agricultural and Food Chemistry 50(2), 319–326 · <a href=\"https://doi.org/10.1021/jf010823n\">doi:10.1021/jf010823n</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Sun et al., 2019 – 2-Furfurylthiol in brewed coffee.</strong> In sealed robusta brew held at 40 °C for 60 min, available 2-furfurylthiol fell by 84%. Reversible binding was the main route of loss; low pH favoured irreversible loss, and hydroxyhydroquinone reacted with it in a model system.</p>\n<p class=\"meta\">Food Chemistry 295, 449–455 · <a href=\"https://doi.org/10.1016/j.foodchem.2019.05.175\">doi:10.1016/j.foodchem.2019.05.175</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Lin et al., 2022 – Acids formed during storage.</strong> Ready-to-drink coffee stored at 30 °C for up to 4 months gained chlorogenic acids and quinic acid. Sensory recombination tests linked the flavour change to the fall in pH rather than to total acidity.</p>\n<p class=\"meta\">Molecules 27(7), 2120 · <a href=\"https://doi.org/10.3390/molecules27072120\">doi:10.3390/molecules27072120</a></p>\n</div>"
}