  "id": "roaster-energy-use",
  "url": "https://coffearium.org/entries/roaster-energy-use/",
  "license": "CC-BY-4.0",
  "title": "Roaster energy use",
  "summary": "How much heat and electricity coffee roasting takes, where the energy goes – beans, water, hot exhaust and afterburner – and how recirculation, heat recovery and the choice of fuel change energy use and carbon dioxide.",
  "domain": "roasting",
  "kind": "Concept",
  "stage": "roast",
  "topics": [
    "sustainability",
    "equipment"
  ],
  "topicSections": {
    "sustainability": {
      "id": "fuels-and-carbon-dioxide",
      "label": "Fuels and carbon dioxide"
    }
  },
  "lang": "en",
  "status": "verified",
  "reviewer": "Coffearium verification pass",
  "lastVerified": "2026-11-16T00:00:00.000Z",
  "literatureSearched": "2026-11-16T00:00:00.000Z",
  "updated": "2026-11-16T00:00:00.000Z",
  "added": "2026-11-16T00:00:00.000Z",
  "brief": [
    "Studies consulted put the heat or fuel for roasting at about 0.7–3.6 MJ per kg of coffee, mostly modelled; boundary and mass basis explain much of the spread.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup>",
    "In a 2023 model of a ground-coffee plant, the roaster took 66–67% of the heat and the afterburner the remaining 33–34%.<sup><a href=\"#src-s1\">1</a></sup>",
    "In the same model, a single-pass roaster without hot-air recirculation raised heat use by 146–167%.<sup><a href=\"#src-s1\">1</a></sup>",
    "A European Commission best-practice page gives savings of about 10–20% for green coffee preheating with exhaust heat in batch roasters, without showing data.<sup><a href=\"#src-s9\">9</a></sup>",
    "Roasting and grinding together contributed a median 8% of the cradle-to-grave carbon footprint of coffee in a 2024 review.<sup><a href=\"#src-s7\">7</a></sup>"
  ],
  "quickFacts": [
    {
      "label": "Heat per kg (studies consulted)",
      "value": "About 0.7–3.6 MJ, mostly modelled; boundary and basis differ (green, roasted or ground coffee)"
    },
    {
      "label": "Afterburner share",
      "value": "33–34% of heat in one model; about half of the natural gas in another (our calculation)"
    },
    {
      "label": "Largest loss",
      "value": "Hot gas leaving the stack (modelling chapter)"
    },
    {
      "label": "Main savings",
      "value": "Recirculation, exhaust heat recovery, green coffee preheating, catalytic instead of thermal afterburning"
    },
    {
      "label": "Usual fuel",
      "value": "Natural gas (US EPA, 1995; permits and plant studies consulted)"
    },
    {
      "label": "Footprint share",
      "value": "Roasting and grinding, median 8% cradle to grave (2024 review)"
    }
  ],
  "aka": [
    "Roasting energy",
    "Roasting energy use",
    "Energy use in roasting",
    "Roaster fuel consumption"
  ],
  "linkTerms": [
    "roaster energy use",
    "roasting energy",
    "energy use in roasting",
    "energy consumption of roasting",
    "roaster fuel use",
    "green coffee preheating",
    "exhaust heat exchanger"
  ],
  "related": [
    "roaster-emissions",
    "carbon-footprint-of-coffee",
    "drum-roaster",
    "fluid-bed-roaster",
    "tangential-and-centrifugal-roasters",
    "airflow",
    "industrial-roasting-history",
    "roast-loss",
    "roast-degree-and-colour",
    "water-in-roasting",
    "endothermic-and-exothermic-phases",
    "cooling-and-quenching",
    "roasting"
  ],
  "contested": [
    "Share of the afterburner in roasting energy: in a 2023 model of a ground-coffee plant with a recirculating batch roaster, the afterburner used 33–34% of the heat<sup><a href=\"#src-s1\">1</a></sup>; in a 2025 model of a small plant in Athens, Greece, with a single-pass roasting chamber in its base case, it burned 19.23 of 37.21 Nm³ of natural gas, about 52% (our calculation)<sup><a href=\"#src-s2\">2</a></sup>; a 2016 exergy study states in its introduction, without a citation, that afterburners can consume up to 400% more fuel than the roaster itself.<sup><a href=\"#src-s3\">3</a></sup> The studies differ in plant, recirculation, oxidiser and boundary, and none of them measured the share across several roasteries."
  ],
  "corrections": [
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "Energy range 0.7–3.6 MJ/kg no longer described as \"afterburner included\" (brief, quick facts, Explained text, chart title and caption); now \"heat or fuel, mostly modelled\", with boundary named: Kekes et al.'s QTOT is roasting plus enthalpy added for cooling (QADD 113.0 kJ/kg), and neither Kekes et al. nor Pantaleo et al. state how the afterburner enters their figure.",
      "reason": "Kekes et al. 2025, Sections 3.1 and Tables 2 and 5 (QTOT = QSR + QADD); Pantaleo et al. 2017 gives one natural-gas figure for a plant whose burner and afterburner are both gas-fired."
    },
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "The 1.67 GJ per tonne value was labelled \"partly measured\" in the chart and set against \"only the 2016 study rests partly on on-site measurements\" in the text; now labelled as stated without a source in the study's introduction, not one of its results. The 400% afterburner statement is likewise marked as uncited introduction text (contested, table, body).",
      "reason": "Vučković et al. 2016, Introduction; neither sentence carries a reference, and the study's own on-site data concern its exergy analysis."
    },
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "European Commission best-practice page (s9); url changed to the print version that carries the full text; savings figures (<10%, about 30%, about 10–20%) now marked in text, table, chart title, caption and brief as given without data or citation; tierNote rewritten with the tier decision; 250–450 °C no longer cited to it (the page attributes it to a roaster maker); retrofit quote corrected to the page's wording (\"While it is possible …\") and the text now adds that the page calls a retrofit more complex.",
      "reason": "Page print version, sections Description, Applicability and Literature; tier rules in docs/AGENT_BRIEF.md (company pages Tier C) applied to figures the page draws from roaster makers."
    },
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "Kekes et al. 2025 base case identified as a single-pass roasting chamber (contested, Afterburner energy, table); natural gas cut with recirculated afterburner air added as about 31% (our calculation, 37.21 to 25.53 Nm³) beside the 21% fall in total energy, which includes cooling; 25% and 18% marked as life-cycle indicators; savings chart row now 21–31%.",
      "reason": "Kekes et al. 2025, Table 3 (\"Single pass\") and Section 3.1; arithmetic rechecked."
    },
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "Worked example (84 g CO₂ per kg green) now shows its inputs (1.5 MJ × 56.1 g/MJ) and states the assumption that the 1.5 MJ is on the net calorific basis of the IPCC factors.",
      "reason": "2006 IPCC Guidelines, Vol. 2, Ch. 1, Section 1.4.1.2 (NCV basis); Pantaleo et al. do not state a calorific basis."
    },
    {
      "date": "2026-11-16T00:00:00.000Z",
      "change": "Nab and Maslin values: \"processing phase\" changed to \"roasting-to-cup stage\", with consumption (70%) named, in line with carbon-footprint-of-coffee.md; EPA sentence on roaster burners as oxidisers no longer adds \"by leading the exhaust back to them\"; IPCC chapter author corrected to Kainou, K.",
      "reason": "Nab and Maslin 2020, Section 6.4; AP-42 9.13.2 (wording); IPCC chapter title page (\"Kainou Kazunari\", family name first)."
    }
  ],
  "sources": [
    {
      "id": "s1",
      "title": "An environmental and economic sustainability assessment of coffee production in the UK",
      "authors": "Gosalvitr, P.; Cuéllar-Franca, R. M.; Smith, R.; Azapagic, A.",
      "year": 2023,
      "publisher": "Chemical Engineering Journal 465, 142793",
      "url": "https://www.sciencedirect.com/science/article/pii/S1385894723015243",
      "doi": "10.1016/j.cej.2023.142793",
      "tier": "A",
      "quote": "The coffee is roasted in a batch roaster with hot air recirculation, as the latter is used commonly in practice to increase the energy efficiency.",
      "quotes": [
        {
          "text": "The functional unit for both system boundaries is defined as the 'production of 1 tonne of ground or instant coffee'.",
          "for": "functional unit"
        },
        {
          "text": "As can be observed in Table S1, the ground coffee production process consumes between 702.7 and 1121.4 MJ of heat",
          "for": "heat per tonne of ground coffee"
        },
        {
          "text": "followed by the afterburner, which consumes the remaining 33–34% of the heat to treat air emissions",
          "for": "afterburner share"
        },
        {
          "text": "In addition to the heat, the production of ground coffee consumes 77.8–95.8 MJ of electricity.",
          "for": "electricity per tonne"
        },
        {
          "text": "Coffee grinding and the cyclone are the main consumers",
          "for": "electricity consumers"
        },
        {
          "text": "using the 'single pass' system increases heat consumption in the production of ground coffee by 146–167%, whereas no significant changes could be observed for electricity consumption (<3%).",
          "for": "single pass versus recirculation"
        },
        {
          "text": "the overall process energy demand increases with the roasting level as the roasting temperature increases",
          "for": "roast degree and energy"
        },
        {
          "text": "the CC of a dark roast ground and instant coffee is 13% and 5% higher than the equivalent light roasted product",
          "for": "dark versus light roast"
        },
        {
          "text": "using silverskin as a fuel would reduce all environmental impacts and costs of both ground and instant coffee production",
          "for": "silverskin as fuel"
        },
        {
          "text": "For gate-to-gate, roasting and packaging are the main contributors to the impacts and costs",
          "for": "roasting as gate-to-gate hotspot"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Life cycle assessment and costing of ground and instant coffee made in the UK; plant modelled in Aspen Plus (batch roaster with hot-air recirculation, afterburner), not measured; per tonne of product; light to dark roasts.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s2",
      "title": "Enhancing Environmental Sustainability in the Coffee Processing Industry via Energy Recovery and Optimization: A Life Cycle Assessment Case Study",
      "authors": "Kekes, T.; Koskinakis, S. E.; Boukouvalas, C.; Krokida, M.",
      "year": 2025,
      "publisher": "Sustainability 17(3), 1334",
      "url": "https://www.mdpi.com/2071-1050/17/3/1334",
      "doi": "10.3390/su17031334",
      "tier": "A",
      "quote": "resulting in a total energy requirement (QTOT) of 3647.7 kJ/kg of raw coffee beans",
      "quotes": [
        {
          "text": "the total energy required to roast a batch of coffee beans (QSR) is 3534.8 kJ/kg of raw coffee beans",
          "for": "roasting energy, base case"
        },
        {
          "text": "the total energy required for roasting (QSR) is reduced to 2425.8 kJ/kg of raw coffee beans",
          "for": "roasting energy with recirculation"
        },
        {
          "text": "the total energy requirement (QTOT) decreases to 2872.4 kJ/kg of raw coffee beans",
          "for": "total energy with recirculation"
        },
        {
          "text": "The added specific enthalpy for the cooling process (QADD) is 113.0 kJ/kg of raw coffee beans.",
          "for": "cooling enthalpy inside the total"
        },
        {
          "text": "the recycling of waste hot air streams of the afterburner significantly reduces the consumption of natural gas",
          "for": "recirculating afterburner air"
        },
        {
          "text": "the total consumption of natural gas (CTOT) significantly decreases from 37.21 Nm3 to 25.53 Nm3",
          "for": "total natural gas"
        },
        {
          "text": "the natural gas consumption in the afterburner (CAB) is decreased from 19.23 Nm3 to 13.19 Nm3",
          "for": "afterburner natural gas"
        },
        {
          "text": "with a raw coffee bean processing capacity of 1800 kg per day",
          "for": "plant size"
        },
        {
          "text": "takes place at temperatures between 190 and 245 °C",
          "for": "roasting temperature"
        },
        {
          "text": "with a total of 0.48 kg CO₂ eq. per kg of raw coffee beans",
          "for": "climate change, base case"
        },
        {
          "text": "Scenario A achieved a 25% reduction in greenhouse gas emissions and an 18% decrease in fossil fuel use",
          "for": "savings in scenario A"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Gate-to-gate LCA, small plant in Athens, Greece (1,800 kg green/day); natural-gas roaster (single-pass chamber in base case, Table 3) and afterburner; model, per kg green. QTOT = QSR + cooling (QADD); Nm³ time basis not stated.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s3",
      "title": "Exergoeconomic evaluation of real processes for coffee roasting",
      "authors": "Vučković, G. D.; Stojiljković, M. M.; Vasiljević, G. M.",
      "year": 2016,
      "publisher": "Thermal Science 20 (Suppl. 5), S1271–S1283",
      "url": "https://thermalscience.vinca.rs/pdfs/papers-2016/TSCI16S5271V.pdf",
      "doi": "10.2298/TSCI16S5271V",
      "tier": "A",
      "quote": "To produce one ton of roasted coffee products (from green beans to roasted coffee beans), a commercial batch coffee roaster with an afterburner consumes about 1.67 GJ of fuel energy.",
      "quotes": [
        {
          "text": "Afterburners can consume up to 400 percent more fuel than the roaster itself.",
          "for": "afterburner fuel"
        },
        {
          "text": "One batch containing 300 kg of green coffee yields approximately 255-260 kg of roasted coffee.",
          "for": "batch size and yield"
        },
        {
          "text": "Afterburners release exhaust gases with a temperature of 250-450 °C, depending on the roasting process",
          "for": "afterburner exhaust temperature"
        },
        {
          "text": "The physical exergy of exhaust gases is 231.20 kW or 37.62% of the total exergy destruction and loss of the system.",
          "for": "exhaust exergy"
        },
        {
          "text": "The value of the overall exergy efficiency of 33.26% indicates that there is a potential for energy improvements",
          "for": "exergy efficiency"
        },
        {
          "text": "For roasters with the capacity of up to 4 tons of green coffee beans per hour, the potential of heat recovery is 1.1 MW and the possibility to save money is around 60,000 € per year.",
          "for": "heat recovery potential"
        },
        {
          "text": "Natural gas, which is used as primary fuel for the roasting process, is supplied from a compressed natural gas (CNG) station to the burners of the batch coffee roasters.",
          "for": "natural gas as fuel"
        },
        {
          "text": "The inputs to the mathematical model are partly data obtained from the onsite measurements.",
          "for": "partly measured data"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Exergy and exergoeconomic analysis of one gas-fired 300 kg batch roaster with afterburner, partly from on-site measurements (plant not named; authors in Serbia). The 1.67 GJ per tonne and the 400% afterburner statement are in the introduction without a citation.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s4",
      "title": "Intermittent waste heat recovery: Investment profitability of ORC cogeneration for batch, gas-fired coffee roasting",
      "authors": "Pantaleo, A. M.; Fordham, J.; Oyewunmi, O. A.; Markides, C. N.",
      "year": 2017,
      "publisher": "Energy Procedia 129, 575–582 (ORC2017)",
      "url": "https://ricerca.uniba.it/retrieve/dd9e0c64-e6ad-1e9c-e053-3a05fe0a45ef/final%20paper-torrefaction.pdf",
      "doi": "10.1016/j.egypro.2017.09.209",
      "tier": "A",
      "quote": "Each cycle requires 1.5 MJ of natural gas fuel per kg of beans, or 375 MJ per cycle.",
      "quotes": [
        {
          "text": "Assuming a heat demand of 1.5 MJ/kg of green beans and a processed mass of 250 kg",
          "for": "assumed heat demand per kg green"
        },
        {
          "text": "The temperature of the exhaust gas from the stack is in the range 300-350 °C",
          "for": "stack temperature"
        },
        {
          "text": "the flue gas is discharged for a duration of about 15 seconds.",
          "for": "intermittent waste heat"
        },
        {
          "text": "The afterburner is also quite energy intensive and releases the final gas at a very high temperature.",
          "for": "afterburner energy"
        },
        {
          "text": "The case study of a major coffee torrefaction firm with 500 kg/hr production capacity is assumed",
          "for": "case study basis"
        }
      ],
      "scope": {
        "claim": "data",
        "context": "Techno-economic case study (ORC, micro gas turbine) for a batch, gas-fired drum plant of 500 kg/h with partial hot gas recycling, Italy; 1.5 MJ/kg green is an assumed natural-gas input (burner and afterburner gas-fired, split not given).",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s5",
      "title": "Batch Coffee Roasting; Roasting Energy Use; Reducing That Use",
      "authors": "Schwartzberg, H.",
      "year": 2013,
      "publisher": "In: Yanniotis, S.; Taoukis, P.; Stoforos, N. G.; Karathanos, V. T. (eds), Advances in Food Process Engineering Research and Applications, Springer (Food Engineering Series), pp. 173–195 (author's text hosted by a coffee retailer)",
      "url": "https://library.sweetmarias.com/wp-content/uploads/2020/08/Coffee-Roasting-Schwartzenberg.pdf",
      "doi": "10.1007/978-1-4614-7906-2_10",
      "tier": "B",
      "tierNote": "Chapter in an edited conference book without stated peer review; used only for statements without numbers",
      "quote": "Nearly 75% of heat input to roasters can go out the stack.",
      "quotes": [
        {
          "text": "Overall enthalpy balances were used to compute QSR, the kJ energy used to roast a kg of green coffee feed in both R and SP roasters.",
          "for": "enthalpy balance per kg green"
        },
        {
          "text": "QSR also = QB + QG + QC from the overall enthalpy balance for the roaster.",
          "for": "where the heat goes"
        },
        {
          "text": "Therefore Q′REAC appears to be negligibly small.",
          "for": "reaction heat"
        },
        {
          "text": "Q′LOSS, the rate of loss of heat from the chamber, is small for well-designed roasters",
          "for": "shell losses"
        },
        {
          "text": "QM/R would be larger for most small roasters",
          "for": "hardware preheating in small roasters"
        },
        {
          "text": "In single-pass (SP) roasters gas passes through the roaster only once.",
          "for": "single-pass definition"
        },
        {
          "text": "Largely bypassing afterburners when VOC concentrations are acceptably low can reduce energy use by about 20%.",
          "for": "afterburner bypass"
        },
        {
          "text": "QTOT is roughly twice as great for thermal afterburning (TAB = 760ºC) as for catalytic afterburning",
          "for": "thermal versus catalytic afterburning"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Enthalpy-balance model of batch, gas-fired roasters with afterburners (recirculating and single-pass), compared with a few published plant values; model, not measurement.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s6",
      "title": "Life cycle assessment of spray dried soluble coffee and comparison with alternatives (drip filter and capsule espresso)",
      "authors": "Humbert, S.; Loerincik, Y.; Rossi, V.; Margni, M.; Jolliet, O.",
      "year": 2009,
      "publisher": "Journal of Cleaner Production 17(15), 1351–1358",
      "url": "https://documents.epfl.ch/groups/m/me/mediacomfiles/www/Humbert%20et%20al%202009%20-%20LCA%20Coffee.pdf",
      "doi": "10.1016/j.jclepro.2009.04.011",
      "tier": "A",
      "quote": "More than half of the environmental impacts of spray dried soluble coffee occur at the use phase.",
      "quotes": [
        {
          "text": "Primary data collected on spray dried soluble coffee and roasted and ground coffee production sites.",
          "for": "plant data (Table 2 title)"
        },
        {
          "text": "roasted and ground coffee manufacturing plant in Spain",
          "for": "plant location"
        }
      ],
      "scope": {
        "claim": "data",
        "context": "Table 2: primary data per kg roasted and ground coffee from one plant in Spain (green coffee handling and cleaning, roasting, grinding, filling and packing, conditioning): 1.23 kg green coffee, 0.14 kWh electricity, 0.07 Nm³ natural gas.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s7",
      "title": "Unravelling life cycle impacts of coffee: Why do results differ so much among studies?",
      "authors": "Chéron-Bessou, C.; Acosta-Alba, I.; Boissy, J.; Payen, S.; Rigal, C.; Setiawan, A. A. R.; Sevenster, M.; Tran, T.; Azapagic, A.",
      "year": 2024,
      "publisher": "Sustainable Production and Consumption 47, 251–266",
      "url": "https://researchonline.jcu.edu.au/85847/1/85847.pdf",
      "doi": "10.1016/j.spc.2024.04.005",
      "tier": "A",
      "quote": "For the former, the GWP values ranged from 0.15 to 14.5 (median: 3.6) kg CO2 eq./kg green coffee beans and for the latter the values ranged from 2 to 23 (median: 8.8) kg CO2 eq./kg consumed coffee in drinks.",
      "quotes": [
        {
          "text": "cup washing and waste management, each accounting for about 18 % (median), packaging (median 9–18 %) and roasting and grinding (median 8 %).",
          "for": "roasting and grinding share"
        },
        {
          "text": "It showed a 1.6-fold difference in energy use from light to dark roasting;",
          "for": "light versus dark roasting energy (Gosalvitr 2021 thesis)"
        },
        {
          "text": "a 10-fold difference in energy used between roasting (higher) and grinding (lower);",
          "for": "roasting versus grinding energy (Gosalvitr 2021 thesis)"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Review of coffee life cycle assessments; median shares across cradle-to-grave studies. The light/dark and roasting/grinding ratios are cited from a 2021 doctoral thesis (Gosalvitr, University of Manchester).",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s8",
      "title": "Life cycle assessment synthesis of the carbon footprint of Arabica coffee: Case study of Brazil and Vietnam conventional and sustainable coffee production and export to the United Kingdom",
      "authors": "Nab, C.; Maslin, M.",
      "year": 2020,
      "publisher": "Geo: Geography and Environment 7(2), e00096",
      "url": "https://discovery.ucl.ac.uk/10118702/1/geo2.96.pdf",
      "doi": "10.1002/geo2.96",
      "tier": "A",
      "quote": "The 77% reduction in carbon footprint for sustainable coffee production in comparison to conventional production was due to exportation of coffee beans via cargo ship rather than freight flight and the reduction of agrochemical inputs.",
      "quotes": [
        {
          "text": "An LCA on coffee processing by PCF Pilotprojekt Deutschland (2008) calculated a carbon footprint of 3.05 kg CO2e kg–1",
          "for": "processing phase footprint"
        },
        {
          "text": "green coffee, with 70% of emissions associated with consumption, followed by grinding (10%), roasting (6%),",
          "for": "roasting share of processing phase"
        }
      ],
      "scope": {
        "claim": "cited",
        "context": "Synthesis LCA of arabica coffee from Brazil and Vietnam to the UK; the processing-phase values are taken from the 2008 German PCF pilot study, not modelled anew.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s9",
      "title": "Reduction of energy use through the adoption of green coffee preheating in batch coffee roasting",
      "authors": "European Commission, Joint Research Centre",
      "publisher": "European Commission, Joint Research Centre, Green Best Practice Community (best environmental management practice, food and beverage manufacturing)",
      "url": "https://greenbestpractice.jrc.ec.europa.eu/print/pdf/node/220",
      "tier": "A",
      "tierNote": "A as a European Commission (JRC) publication for its description of the technique and its applicability. Its savings figures (<10%, about 30%, about 10–20%) show no data and carry no citation; its literature is mostly roaster makers and personal communications from roasting companies. The entry reports them as the page's statements, says so in the text, and uses no other number from it alone; the 250–450 °C exhaust range it attributes to a roaster maker is not cited to it.",
      "quote": "The green coffee pre-heating system can be used only with batch roasters and it is connected upstream of the roaster.",
      "quotes": [
        {
          "text": "Each of the techniques mentioned potentially allows significant energy savings in the roasting operation",
          "for": "savings by technique"
        },
        {
          "text": "from less than 10% in the case of heat exchangers installed in the exhaust gas ducting",
          "for": "exhaust heat exchangers"
        },
        {
          "text": "to approx.30% in the case of roast gas recirculation machines",
          "for": "roast gas recirculation"
        },
        {
          "text": "significant energy savings (in a range of about 10-20%",
          "for": "preheating savings"
        },
        {
          "text": "The green coffee is preheated in the preheating stage up to a certain temperature level (80-100°C).",
          "for": "preheating temperature"
        },
        {
          "text": "This equipment does not require any additional heat energy.",
          "for": "no extra heat for preheater"
        },
        {
          "text": "recirculating the exhaust gases from the roasting of the previous batch",
          "for": "heat from previous batch"
        },
        {
          "text": "While it is possible to retrofit an existing roaster with a preheater",
          "for": "retrofit"
        },
        {
          "text": "it has to be recognised that this is more complex than installation in a new coffee roaster",
          "for": "retrofit more complex"
        },
        {
          "text": "taking into account costs, space requirements, building work etc.",
          "for": "costs and space"
        },
        {
          "text": "Coffee roasting has a high demand for thermal energy",
          "for": "thermal energy demand"
        }
      ],
      "scope": {
        "claim": "guidance",
        "context": "European Commission (JRC) best-practice page for batch coffee roasting, full text in the print version; literature 2006–2015, accessed 2013–2015; savings ranges without data or citation; references mostly roaster makers and personal communications.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s10",
      "title": "2006 IPCC Guidelines for National Greenhouse Gas Inventories, Volume 2: Energy, Chapter 1: Introduction",
      "authors": "Garg, A.; Kainou, K.; Pulles, T.",
      "year": 2006,
      "publisher": "Intergovernmental Panel on Climate Change (IPCC), IGES, Japan",
      "url": "https://www.ipcc-nggip.iges.or.jp/public/2006gl/pdf/2_Volume2/V2_1_Ch1_Introduction.pdf",
      "tier": "A",
      "quote": "These emission factors are default values that are suggested only if country-specific factors are not available.",
      "quotes": [
        {
          "text": "so the default emission factors in Table 1.4 are derived on the assumption of 100 percent oxidation.",
          "for": "full oxidation assumed"
        },
        {
          "text": "These Guidelines use net calorific values (NCVs)",
          "for": "net calorific basis"
        }
      ],
      "scope": {
        "claim": "data",
        "context": "Table 1.4, default CO2 emission factors for combustion: natural gas 56,100 kg/TJ (54,300–58,300), liquefied petroleum gases 63,100 kg/TJ (61,600–65,600).",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s11",
      "title": "AP-42, Fifth Edition, Section 9.13.2: Coffee Roasting",
      "authors": "U.S. Environmental Protection Agency",
      "year": 1995,
      "publisher": "U.S. EPA, Compilation of Air Pollutant Emission Factors",
      "url": "https://www.epa.gov/sites/default/files/2020-10/documents/c9s13-2.pdf",
      "tier": "A",
      "quote": "Gaseous emissions from roasting operations are typically ducted to a thermal oxidizer or thermal catalytic oxidizer",
      "quotes": [
        {
          "text": "carbon monoxide (CO) and carbon dioxide (CO2) emissions are expected as a result of fuel combustion",
          "for": "CO and CO2 from fuel"
        },
        {
          "text": "Because roasters are typically natural gas-fired,",
          "for": "natural gas as usual fuel"
        },
        {
          "text": "Some facilities use the burners that heat the roaster as thermal oxidizers.",
          "for": "roaster burner as oxidiser"
        },
        {
          "text": "which is 93°C to 260°C (200°F to 500°F) more than the maximum temperature of most roasters",
          "for": "oxidiser hotter than roaster"
        }
      ],
      "scope": {
        "claim": "data",
        "context": "US emission factors (September 1995), per short ton of green coffee fed; CO2 batch roaster 180 lb/ton uncontrolled and 530 lb/ton with thermal oxidiser, rating D.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s12",
      "title": "Better Buzz 8345 AB3205 Eng Evaluation (engineering evaluation of a coffee roaster with catalytic afterburner)",
      "authors": "San Diego County Air Pollution Control District (SDAPCD)",
      "year": 2024,
      "publisher": "SDAPCD, San Diego, California (local regulation; permit evaluation signed 28 August 2024)",
      "url": "https://sdapcd.org/content/dam/sdapcd/documents/permits/public-notices/Better-Buzz-8345-AB3205-Eng-Evaluation.pdf",
      "tier": "A",
      "tierNote": "Local regulation; one permit of one Californian air district, binding only for that plant",
      "quote": "Smoke and odor from the roasting process are captured and controlled by the afterburner.",
      "quotes": [
        {
          "text": "0.40 MMBtu/hour natural gas burner with catalytic afterburner",
          "for": "roaster burner rating"
        },
        {
          "text": "with 0.30 MMBtu/hour natural gas burner.",
          "for": "afterburner burner rating"
        },
        {
          "text": "616 lbs/hour roasting capacity",
          "for": "roaster capacity"
        }
      ],
      "scope": {
        "claim": "data",
        "context": "Permit evaluation of one drum roaster (model 'US Millennium 70 Kilo', 616 lb/h) with a catalytic afterburner, San Diego, 2024; burner ratings, not measured fuel use.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    },
    {
      "id": "s13",
      "title": "Energy and airflow optimization in an industrial roasting system: A case study",
      "authors": "Dimchev, I.",
      "year": 2026,
      "publisher": "E3S Web of Conferences 727, 01003 (EEPES 2026 proceedings)",
      "url": "https://www.e3s-conferences.org/articles/e3sconf/pdf/2026/45/e3sconf_eepes2026_01003.pdf",
      "doi": "10.1051/e3sconf/202672701003",
      "tier": "B",
      "quote": "A minimum transport velocity is required to ensure effective transport of solid particles",
      "quotes": [
        {
          "text": "the exhaust fan operated at a constant speed (2.5 kW)",
          "for": "fan before retrofit"
        },
        {
          "text": "reduces the average power requirement to 49% of the nominal value",
          "for": "fan after variable-speed drive"
        }
      ],
      "scope": {
        "claim": "finding",
        "context": "Energy audit of the exhaust system of two identical industrial drum roasters with cyclone and afterburner; fan retrofit with a variable-speed drive; no fuel figures; peer review not stated.",
        "checked": "2026-11-16T00:00:00.000Z"
      },
      "accessed": "2026-11-16T00:00:00.000Z"
    }
  ],
  "markdown": "## How much energy a roast takes\n\nRoasting heats green coffee to high temperatures: between about 190 and 245 °C in one plant study.<sup><a href=\"#src-s2\">2</a></sup> In the plants studied, the heat came from burning natural gas.<sup><a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup> The European Commission describes roasting as having a high demand for thermal energy.<sup><a href=\"#src-s9\">9</a></sup>\n\nStudies give the energy as megajoules (MJ) per kilogram of coffee. Those consulted for this entry report about 0.7 to 3.6 MJ of heat or fuel per kg, mostly from models.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup> A model of a UK ground-coffee plant gave the low end.<sup><a href=\"#src-s1\">1</a></sup> A model of a small plant in Athens, Greece, gave the high end.<sup><a href=\"#src-s2\">2</a></sup>\n\nPart of the spread comes from what is counted. Some studies count per kg of green coffee, others per kg of roasted or ground coffee.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a></sup> Some include the afterburner; one adds the heat for cooling.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a></sup> Roasted coffee weighs less than the green coffee it came from. In one plant, 300 kg of green coffee gave about 255–260 kg of roasted coffee.<sup><a href=\"#src-s3\">3</a></sup> The same energy therefore looks larger per kg roasted than per kg green. The roast loss entry explains the mass change.\n\n<figure>\n<div data-figure=\"roaster-energy-use-specific-heat\"></div>\n<figcaption>Heat or fuel for roasting per kilogram of coffee in four studies. Three values come from two models, one is an assumed input and one is stated without a source. Boundary and mass basis differ, so the rows are not directly comparable.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s4\">4</a></sup></figcaption>\n</figure>\n\n## Where the heat goes\n\nA roaster's heat ends up in three places, according to a modelling chapter: the beans, the gas leaving the stack and the chaff.<sup><a href=\"#src-s5\">5</a></sup> In the beans, heat warms the seed and evaporates its water. The water in roasting entry covers that part.\n\n**The stack.** The gas leaving the roaster is still hot. According to the modelling chapter, most of the heat input can leave through the stack.<sup><a href=\"#src-s5\">5</a></sup> After an afterburner, the exhaust is at about 250–450 °C.<sup><a href=\"#src-s3\">3</a></sup>\n\n**The afterburner.** An afterburner burns the smoke and odour in the exhaust (see Roaster emissions). It needs fuel of its own. In a 2023 model, it used a third of the plant's heat.<sup><a href=\"#src-s1\">1</a></sup> In a 2025 model, it burned about half of the natural gas (our calculation).<sup><a href=\"#src-s2\">2</a></sup>\n\n**Small losses.** The modelling chapter calls heat lost through the roaster's walls small for well-designed roasters.<sup><a href=\"#src-s5\">5</a></sup> It finds the heat released by roasting reactions negligibly small in its balance.<sup><a href=\"#src-s5\">5</a></sup>\n\n**Electricity.** Fans, drives and grinders run on electricity. In the 2023 model, a ground-coffee plant used far less electricity than heat; grinding and the cyclone were the main users.<sup><a href=\"#src-s1\">1</a></sup>\n\n<figure>\n<div data-figure=\"roaster-energy-use-heat-flows\"></div>\n<ol class=\"fig-legend\">\n<li data-n=\"1\"><span><b>Fuel and electricity.</b> Gas for the burners; electricity for fans and drives.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s4\">4</a></sup></span></li>\n<li data-n=\"2\"><span><b>Burner.</b> Heats the process gas.<sup><a href=\"#src-s5\">5</a></sup></span></li>\n<li data-n=\"3\"><span><b>Drum.</b> Heat goes into the beans: warming them and evaporating water; chaff comes off.<sup><a href=\"#src-s5\">5</a></sup></span></li>\n<li data-n=\"4\"><span><b>Cyclone.</b> Separates the chaff from the gas.<sup><a href=\"#src-s5\">5</a></sup></span></li>\n<li data-n=\"5\"><span><b>Recirculation.</b> Part of the hot gas returns to the burner; a single-pass roaster has no loop and needs more heat.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s5\">5</a></sup></span></li>\n<li data-n=\"6\"><span><b>Afterburner.</b> Has its own burner: a third of the heat in one model, about half of the natural gas in another.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a></sup></span></li>\n<li data-n=\"7\"><span><b>Hot exhaust.</b> Leaves at about 250–450 °C.<sup><a href=\"#src-s3\">3</a></sup></span></li>\n<li data-n=\"8\"><span><b>Stack.</b> Hot gas through the stack is the largest loss.<sup><a href=\"#src-s5\">5</a></sup></span></li>\n<li data-n=\"9\"><span><b>Exhaust heat exchanger.</b> Recovers heat from the exhaust duct.<sup><a href=\"#src-s9\">9</a></sup></span></li>\n<li data-n=\"10\"><span><b>Green coffee preheater.</b> Exhaust heat warms the next batch to 80–100 °C (batch roasters only).<sup><a href=\"#src-s9\">9</a></sup></span></li>\n<li data-n=\"11\"><span><b>Hot afterburner air.</b> Returned to the roaster's burner.<sup><a href=\"#src-s2\">2</a></sup></span></li>\n</ol>\n<figcaption>Where the energy of a batch roaster with recirculation and afterburner goes, and where heat can be recovered.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s5\">5</a>,<a href=\"#src-s9\">9</a>,<a href=\"#src-s11\">11</a></sup> Schematic, not to scale.</figcaption>\n</figure>\n\n## Ways to use less energy\n\n**Recirculation.** A recirculating roaster sends part of its hot gas back to the burner. The 2023 model assumed such a roaster, as common in practice.<sup><a href=\"#src-s1\">1</a></sup> Without recirculation, in a single-pass roaster, the plant's heat use rose by 146–167%.<sup><a href=\"#src-s1\">1</a></sup> A single-pass roaster is one in which the gas passes through only once.<sup><a href=\"#src-s5\">5</a></sup>\n\n**Heat recovery.** Heat can be taken from the hot exhaust. The European Commission's best-practice page puts savings at less than 10% for exhaust heat exchangers.<sup><a href=\"#src-s9\">9</a></sup> It gives about 30% for roasters that recirculate roast gas.<sup><a href=\"#src-s9\">9</a></sup> The page shows no data or source for these figures.<sup><a href=\"#src-s9\">9</a></sup>\n\n**Green coffee preheating.** Exhaust heat from the previous batch can warm the next batch of green coffee to 80–100 °C.<sup><a href=\"#src-s9\">9</a></sup> This works only with batch roasters and needs no additional heat.<sup><a href=\"#src-s9\">9</a></sup> The same page gives savings of about 10–20%, again without data.<sup><a href=\"#src-s9\">9</a></sup>\n\n**Afterburner choice.** A catalytic afterburner works at a lower temperature than a thermal one.<sup><a href=\"#src-s11\">11</a></sup> The modelling chapter finds much higher total energy use with thermal afterburning.<sup><a href=\"#src-s5\">5</a></sup> It also proposes largely bypassing the afterburner when emissions are low enough.<sup><a href=\"#src-s5\">5</a></sup>\n\n**Roast degree.** In the 2023 model, energy demand rose with roast degree, because darker roasts reach higher temperatures.<sup><a href=\"#src-s1\">1</a></sup>\n\n<figure>\n<div data-figure=\"roaster-energy-use-savings\"></div>\n<figcaption>Energy savings reported for heat recovery and recirculation in batch roasting. Three ranges come from a European Commission best-practice page that shows no data for them; one modelled case is our calculation.<sup><a href=\"#src-s2\">2</a>,<a href=\"#src-s9\">9</a></sup></figcaption>\n</figure>\n\n## Fuels and carbon dioxide\n\n**Fuels.** The United States Environmental Protection Agency (EPA) describes roasters as typically fired with natural gas.<sup><a href=\"#src-s11\">11</a></sup> Three plant studies and one permit consulted for this entry also name natural gas.<sup><a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a>,<a href=\"#src-s6\">6</a>,<a href=\"#src-s12\">12</a></sup> Burning fuel produces carbon monoxide and carbon dioxide.<sup><a href=\"#src-s11\">11</a></sup>\n\n**Carbon dioxide per unit of fuel.** The Intergovernmental Panel on Climate Change (IPCC) gives default factors for national inventories.<sup><a href=\"#src-s10\">10</a></sup> Liquefied petroleum gas (LPG) emits more carbon dioxide per unit of energy than natural gas.<sup><a href=\"#src-s10\">10</a></sup> For electricity, emissions depend on how it is generated; no study consulted for this entry compared electric and gas-fired roasters.\n\n**Chaff as fuel.** Silverskin, the chaff that comes off the beans, can be burnt for heat. In the 2023 model, doing so lowered all environmental impacts and costs.<sup><a href=\"#src-s1\">1</a></sup>\n\n**Share of the footprint.** Roasting is a small part of coffee's carbon footprint. In a 2024 review, roasting and grinding together contributed a median 8% in cradle-to-grave studies.<sup><a href=\"#src-s7\">7</a></sup> Inside the roastery, roasting matters more: it was a main contributor to the plant's impacts in the 2023 model.<sup><a href=\"#src-s1\">1</a></sup> The carbon footprint of coffee entry covers the whole chain; the roaster emissions entry covers smoke and its cleaning.\n\n<!-- deep-dive -->\n\n## Reference values\n\nValues reported in the sources, with their basis. Energy in kJ per kg equals MJ per tonne. Conversions marked ≈ are ours.\n\n| Parameter | Value reported | Basis and conditions | Source |\n|---|---|---|---|\n| Heat, ground-coffee plant | 702.7–1,121.4 MJ per tonne (≈0.70–1.12 MJ/kg), across the modelled roast degrees (light to dark) | Per tonne ground coffee; model, batch roaster with hot-air recirculation, roaster plus afterburner | Gosalvitr et al.<sup><a href=\"#src-s1\">1</a></sup> |\n| Afterburner share of heat | 33–34%; roaster 66–67% | Same model | Gosalvitr et al.<sup><a href=\"#src-s1\">1</a></sup> |\n| Electricity, ground-coffee plant | 77.8–95.8 MJ per tonne | Same model; grinding and cyclone main consumers | Gosalvitr et al.<sup><a href=\"#src-s1\">1</a></sup> |\n| Single-pass instead of recirculating roaster | Heat use +146–167%; no significant change in electricity | Same model | Gosalvitr et al.<sup><a href=\"#src-s1\">1</a></sup> |\n| Energy to roast (QSR), base | 3,534.8 kJ/kg | Per kg green; model of a 1,800 kg/day plant, Athens; single-pass roasting chamber | Kekes et al.<sup><a href=\"#src-s2\">2</a></sup> |\n| Total energy (QTOT), base / afterburner air recirculated | 3,647.7 / 2,872.4 kJ/kg (≈21% less) | Per kg green; same model; QTOT = roasting plus enthalpy added for cooling (113.0 kJ/kg in the base case) | Kekes et al.<sup><a href=\"#src-s2\">2</a></sup> |\n| Natural gas, total / afterburner, base | 37.21 / 19.23 Nm³ (afterburner ≈52%) | Same model; time basis not stated | Kekes et al.<sup><a href=\"#src-s2\">2</a></sup> |\n| Natural gas, total / afterburner, recirculated | 25.53 / 13.19 Nm³ (total ≈31% less than base) | Same model | Kekes et al.<sup><a href=\"#src-s2\">2</a></sup> |\n| Fuel, batch roaster with afterburner | ≈1.67 GJ per tonne roasted coffee (≈1.67 MJ/kg, ≈1,670 kJ/kg) | Stated without a citation in the introduction of an exergy study; not one of its results | Vučković et al.<sup><a href=\"#src-s3\">3</a></sup> |\n| Afterburner fuel | Up to 400% more than the roaster itself | Same introduction, without a citation | Vučković et al.<sup><a href=\"#src-s3\">3</a></sup> |\n| Overall exergy efficiency | 33.26% | One 300 kg batch roaster with afterburner; partly on-site data | Vučković et al.<sup><a href=\"#src-s3\">3</a></sup> |\n| Heat recovery potential | 1.1 MW; about EUR 60,000 a year (2016) | Roasters up to 4 t of green coffee per hour | Vučković et al.<sup><a href=\"#src-s3\">3</a></sup> |\n| Natural gas per kg green | 1.5 MJ/kg (1,500 kJ/kg; 375 MJ per 250 kg cycle) | Assumed input, batch drum with partial hot gas recycling, 500 kg/h | Pantaleo et al.<sup><a href=\"#src-s4\">4</a></sup> |\n| Stack gas temperature | 300–350 °C | Same case study | Pantaleo et al.<sup><a href=\"#src-s4\">4</a></sup> |\n| Afterburner exhaust temperature | 250–450 °C | Exergy study (abstract) | Vučković et al.<sup><a href=\"#src-s3\">3</a></sup> |\n| Whole roast-and-ground plant | 0.14 kWh electricity; 0.07 Nm³ natural gas; 1.23 kg green coffee | Per kg roasted and ground coffee; one plant in Spain, all steps from cleaning to packing | Humbert et al.<sup><a href=\"#src-s6\">6</a></sup> |\n| Savings, exhaust heat exchangers | Less than 10% | Batch roasting; best-practice page, no data or citation shown | JRC<sup><a href=\"#src-s9\">9</a></sup> |\n| Savings, roast gas recirculation | ≈30% | Same; no data or citation shown | JRC<sup><a href=\"#src-s9\">9</a></sup> |\n| Savings, green coffee preheating | About 10–20%; beans preheated to 80–100 °C | Batch roasters only; depends on roasting time, roast degree and exhaust treatment; no data or citation shown | JRC<sup><a href=\"#src-s9\">9</a></sup> |\n| Burner ratings, one permit | Roaster 0.40 MMBtu/h (≈117 kW); catalytic afterburner 0.30 MMBtu/h (≈88 kW) | 616 lb/h (≈279 kg/h) roaster; ratings, not fuel use | SDAPCD<sup><a href=\"#src-s12\">12</a></sup> |\n| CO₂ factor, natural gas | 56,100 kg/TJ (54,300–58,300) (≈56.1 g/MJ) | Default, 100% oxidation | IPCC<sup><a href=\"#src-s10\">10</a></sup> |\n| CO₂ factor, LPG | 63,100 kg/TJ (61,600–65,600) (≈63.1 g/MJ) | Same | IPCC<sup><a href=\"#src-s10\">10</a></sup> |\n| CO₂, batch roaster, uncontrolled / with thermal oxidiser | 180 / 530 lb per ton green coffee (≈90 / 265 kg/t); rating D | US emission factors, 1995 | EPA AP-42<sup><a href=\"#src-s11\">11</a></sup> |\n| Roasting and grinding, share of footprint | Median 8% | Cradle to grave, review of studies | Chéron-Bessou et al.<sup><a href=\"#src-s7\">7</a></sup> |\n| Roasting, share of roasting-to-cup stage | 6% of 3.05 kg CO₂e per kg green coffee; grinding 10%; consumption 70% | 2008 German pilot study, as cited | Nab & Maslin<sup><a href=\"#src-s8\">8</a></sup> |\n\n## The energy balance of a roaster\n\n**The balance.** A modelling chapter computes the energy to roast a kilogram of green coffee from overall enthalpy balances.<sup><a href=\"#src-s5\">5</a></sup> The heat input equals the heat taken up by the beans, the heat in the gas leaving the stack and the heat in the chaff.<sup><a href=\"#src-s5\">5</a></sup> According to the chapter, the heat released by roasting reactions is negligibly small in that balance, and wall losses are small for well-designed roasters.<sup><a href=\"#src-s5\">5</a></sup> The endothermic and exothermic phases entry covers the reaction heat inside the bean.\n\n**Stack gas dominates.** According to the chapter, most of the heat input can leave through the stack.<sup><a href=\"#src-s5\">5</a></sup> An exergy analysis points the same way. Exergy is the part of energy that can still do work; it falls as heat flows to lower temperatures. In one 300 kg gas-fired batch roaster with an afterburner, the overall exergy efficiency was 33.26%.<sup><a href=\"#src-s3\">3</a></sup> Exhaust gases carried 37.62% of the exergy destroyed and lost in the system.<sup><a href=\"#src-s3\">3</a></sup>\n\n**Basis.** The 2016 study states about 1.67 GJ of fuel energy per tonne of roasted coffee for a commercial batch roaster with an afterburner, without a citation for the figure.<sup><a href=\"#src-s3\">3</a></sup> The 2025 model reports 3,647.7 kJ per kg of green coffee in its base case, of which 3,534.8 kJ/kg for roasting.<sup><a href=\"#src-s2\">2</a></sup> The 2023 model reports 702.7–1,121.4 MJ of heat per tonne of ground coffee.<sup><a href=\"#src-s1\">1</a></sup> The total adds about 113 kJ/kg of enthalpy for cooling to the roasting energy.<sup><a href=\"#src-s2\">2</a></sup> A 2017 case study assumed 1.5 MJ of natural gas per kg of green coffee.<sup><a href=\"#src-s4\">4</a></sup> The 2016 study's own exergy analysis rests partly on on-site measurements, but its 1.67 GJ figure is not one of its results.<sup><a href=\"#src-s3\">3</a></sup>\n\n**A plant as a whole.** One life cycle study collected primary data from a roast-and-ground coffee plant in Spain.<sup><a href=\"#src-s6\">6</a></sup> Per kg of roasted and ground coffee, the plant used 0.14 kWh of electricity and 0.07 Nm³ (normal cubic metres) of natural gas, and 1.23 kg of green coffee.<sup><a href=\"#src-s6\">6</a></sup> These figures cover every step from green coffee cleaning to packing, not roasting alone.<sup><a href=\"#src-s6\">6</a></sup>\n\n## Afterburner energy\n\nA separate thermal oxidiser runs hotter than the roaster. The EPA gives its desired operating temperature as 93–260 °C above the maximum temperature of most roasters.<sup><a href=\"#src-s11\">11</a></sup> Some plants use the burners that heat the roaster as the oxidiser instead.<sup><a href=\"#src-s11\">11</a></sup>\n\nThe share of fuel the afterburner takes differs between studies (see Contested). In the 2023 model, the afterburner used 33–34% of the plant's heat.<sup><a href=\"#src-s1\">1</a></sup> In the 2025 base case, with a single-pass roasting chamber, it burned 19.23 of 37.21 Nm³ of natural gas, about 52% (our calculation).<sup><a href=\"#src-s2\">2</a></sup> The 2016 study states in its introduction, without a citation, that afterburners can consume up to 400% more fuel than the roaster.<sup><a href=\"#src-s3\">3</a></sup> A 2017 case study calls the afterburner quite energy intensive.<sup><a href=\"#src-s4\">4</a></sup>\n\nPermits list burner ratings, not fuel use. In one San Diego permit, a roaster of 616 lb/h (≈279 kg/h) had a 0.40 MMBtu/h (≈117 kW) burner, its catalytic afterburner a 0.30 MMBtu/h (≈88 kW) burner.<sup><a href=\"#src-s12\">12</a></sup>\n\n**Thermal or catalytic.** A catalytic oxidiser reaches the same control efficiency at a lower operating temperature.<sup><a href=\"#src-s11\">11</a></sup> The modelling chapter predicts much higher total energy use with thermal than with catalytic afterburning.<sup><a href=\"#src-s5\">5</a></sup> No measured comparison of the two on the same roaster was found in the sources consulted.\n\n## Recirculation, heat recovery and preheating\n\n**Recirculation.** The 2023 model assumes a batch roaster with hot-air recirculation, as commonly used in practice to raise energy efficiency.<sup><a href=\"#src-s1\">1</a></sup> Switching to a single-pass system raised heat consumption for ground coffee by 146–167%, with no significant change in electricity.<sup><a href=\"#src-s1\">1</a></sup> In the 2025 model, recirculating hot air from the afterburner cut total natural gas from 37.21 to 25.53 Nm³.<sup><a href=\"#src-s2\">2</a></sup> That is about 31% less natural gas (our calculation).<sup><a href=\"#src-s2\">2</a></sup> Total energy, which includes cooling, fell from 3,647.7 to 2,872.4 kJ/kg, about 21% less (our calculation).<sup><a href=\"#src-s2\">2</a></sup> The authors report a 25% cut in greenhouse gas emissions and an 18% cut in fossil fuel use, both life-cycle indicators, for that scenario.<sup><a href=\"#src-s2\">2</a></sup> Recirculation and its history are covered in Industrial roasting history and Airflow.\n\n**Exhaust heat exchangers.** The European Commission page gives savings from less than 10% for exhaust heat exchangers to about 30% for roast gas recirculation machines.<sup><a href=\"#src-s9\">9</a></sup> It shows no data and no citation for these figures; its literature consists mostly of roaster makers' documents and personal communications from roasting companies.<sup><a href=\"#src-s9\">9</a></sup>\n\n**Green coffee preheating.** In this method, exhaust gases from the previous batch warm the next batch to 80–100 °C before it enters the roaster.<sup><a href=\"#src-s9\">9</a></sup> The preheater sits upstream of a batch roaster and needs no additional heat.<sup><a href=\"#src-s9\">9</a></sup> The page gives savings of about 10–20%, alone or combined with other measures, depending on roasting time, roast degree and exhaust air treatment; it shows no data for this range.<sup><a href=\"#src-s9\">9</a></sup> Existing roasters can be retrofitted, though the page calls this more complex than installing a preheater on a new roaster.<sup><a href=\"#src-s9\">9</a></sup>\n\n**Waste heat to power.** In a batch plant, hot flue gas leaves in pulses. A 2017 case study found it discharged for about 15 seconds per cycle, at a stack temperature of 300–350 °C.<sup><a href=\"#src-s4\">4</a></sup> The authors assessed organic Rankine cycle and micro gas turbine units to turn this heat into electricity.<sup><a href=\"#src-s4\">4</a></sup> For roasters of up to 4 t/h, the 2016 study put the heat recovery potential at 1.1 MW and possible savings at about EUR 60,000 a year (2016).<sup><a href=\"#src-s3\">3</a></sup>\n\n**Bypassing the afterburner.** The modelling chapter proposes largely bypassing the afterburner when concentrations of volatile organic compounds are low enough.<sup><a href=\"#src-s5\">5</a></sup> Whether this is allowed depends on the plant's permit; the roaster emissions entry gives examples of permit conditions.\n\n## Roast degree, batch size and electricity\n\n**Roast degree.** In the 2023 model, process energy rose with roast degree because roasting temperature rose.<sup><a href=\"#src-s1\">1</a></sup> Its gate-to-gate climate change impact was 13% higher for dark-roast than for light-roast ground coffee.<sup><a href=\"#src-s1\">1</a></sup> A 2024 review cites a doctoral thesis by the same first author that found a 1.6-fold difference in energy use from light to dark roasting.<sup><a href=\"#src-s7\">7</a></sup>\n\n**Batch size and preheating the roaster.** Before the first batch, the roasting chamber and its metal must be heated. According to the modelling chapter, the heat that goes into roaster hardware, per kg of coffee, is larger for most small roasters.<sup><a href=\"#src-s5\">5</a></sup> No study consulted for this entry measured warm-up or idle energy, or energy per kg across batch sizes on one roaster.\n\n**Electricity.** In the 2023 model, a tonne of ground coffee took 77.8–95.8 MJ of electricity against 702.7–1,121.4 MJ of heat.<sup><a href=\"#src-s1\">1</a></sup> Grinding and the cyclone were the main consumers.<sup><a href=\"#src-s1\">1</a></sup> The review cites a 10-fold difference in energy use between roasting and grinding.<sup><a href=\"#src-s7\">7</a></sup> One energy audit of two industrial drum roasters fitted a variable-speed drive to the exhaust fan and reported lower fan power.<sup><a href=\"#src-s13\">13</a></sup>\n\n## Energy in life-cycle studies\n\n**Small share of the whole.** In a 2024 review, roasting and grinding together contributed a median 8% of the cradle-to-grave footprint.<sup><a href=\"#src-s7\">7</a></sup> A 2020 synthesis took its roasting-to-cup values from a 2008 German pilot study: 3.05 kg CO₂e per kg green coffee, of which consumption 70%, grinding 10% and roasting 6%.<sup><a href=\"#src-s8\">8</a></sup> On those figures, roasting came to about 0.18 kg CO₂e per kg green coffee (our calculation).\n\n**Large share of the roastery.** Gate to gate, the picture changes. In the 2023 model, roasting and packaging were the main contributors to the impacts and costs.<sup><a href=\"#src-s1\">1</a></sup> In the 2025 model, the base plant came to 0.48 kg CO₂e per kg of green coffee.<sup><a href=\"#src-s2\">2</a></sup>\n\n### A worked example for natural gas\n\nThe IPCC's default factor for natural gas is 56,100 kg CO₂ per TJ, that is 56.1 g per MJ; for LPG it is 63,100 kg per TJ.<sup><a href=\"#src-s10\">10</a></sup> The factors assume 100% oxidation and apply where no country-specific factors exist.<sup><a href=\"#src-s10\">10</a></sup> Worked example, our calculation: at the 1.5 MJ of natural gas per kg green coffee assumed in the 2017 case study, burning the gas releases about 84 g CO₂ per kg (1.5 MJ × 56.1 g/MJ).<sup><a href=\"#src-s4\">4</a>,<a href=\"#src-s10\">10</a></sup> This assumes the 1.5 MJ is on the net calorific basis that the IPCC factors use; the case study does not state its basis.<sup><a href=\"#src-s10\">10</a></sup> It counts combustion only, not gas supply chains.\n\nThe EPA's 1995 factors for carbon dioxide from a batch roaster are 180 lb per ton of green coffee without and 530 lb per ton with a thermal oxidiser (≈90 and 265 kg per tonne).<sup><a href=\"#src-s11\">11</a></sup> The EPA expects carbon monoxide and carbon dioxide from fuel combustion.<sup><a href=\"#src-s11\">11</a></sup> The factors do not separate carbon dioxide from the fuel and from the beans; the roaster emissions entry gives the full table.\n\n## Measuring roaster energy use\n\n- **Plant data.** Life cycle studies collect fuel and electricity use per kg of product from plant records.<sup><a href=\"#src-s6\">6</a></sup> These figures include every step in the plant, not roasting alone.\n- **Enthalpy balances.** Models compute heat per kg of green coffee from measured or assumed temperatures and flows.<sup><a href=\"#src-s2\">2</a>,<a href=\"#src-s5\">5</a></sup> The 2016 exergy study combined such a model with on-site measurements.<sup><a href=\"#src-s3\">3</a></sup>\n- **Process simulation.** The 2023 study modelled the plant in process simulation software, not from plant records.<sup><a href=\"#src-s1\">1</a></sup>\n- **Basis.** A value needs its basis: per kg green, roasted or ground coffee, heat or fuel, roaster alone or with afterburner.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s3\">3</a></sup> No standard measurement protocol for roaster energy was found in the sources consulted.\n\n## Risks and trade-offs\n\n- **Afterburner versus energy.** Burning the smoke costs fuel and adds carbon dioxide.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s11\">11</a></sup> Bypassing it saves energy only where emissions and the permit allow.<sup><a href=\"#src-s5\">5</a></sup>\n- **Intermittent heat.** In batch plants, hot flue gas comes in short pulses, which makes heat recovery harder to use.<sup><a href=\"#src-s4\">4</a></sup>\n- **Cost and space.** Retrofitting a preheater has to be weighed against costs and space.<sup><a href=\"#src-s9\">9</a></sup> The 2016 study's heat recovery case was calculated for large roasters of up to 4 t/h.<sup><a href=\"#src-s3\">3</a></sup>\n- **Recirculated gas.** Recirculating systems must always vent part of their off-gas; the roaster emissions entry explains why.\n\n## Open questions\n\n- **Measured energy across roasteries.** Most values consulted are modelled or assumed.<sup><a href=\"#src-s1\">1</a>,<a href=\"#src-s2\">2</a>,<a href=\"#src-s4\">4</a></sup> No study consulted for this entry measured fuel use per kg across many roasteries of different sizes.\n- **Electric roasters.** No study consulted for this entry measured the energy use of electrically heated production roasters, or compared them with gas-fired roasters on a life-cycle basis.\n- **Drum, fluid-bed and continuous roasters.** No study consulted for this entry compared the specific energy of these designs under the same conditions.\n- **Warm-up and idle time.** How much energy a shop roaster uses before its first batch and between batches was not found in the sources consulted.\n- **Afterburner share.** The studies consulted disagree on how much of the fuel goes to the afterburner (see Contested).\n\n## Key studies\n\n<div class=\"study\">\n<p><strong>Gosalvitr et al., 2023 – Ground and instant coffee in the UK.</strong> A life cycle assessment and costing of coffee plants modelled in process simulation software, from light to dark roasts. In ground-coffee production, roasting took two thirds of the heat and the afterburner one third; a single-pass roaster would have raised heat use by 146–167%, and dark roasts had a higher climate impact than light ones.</p>\n<p class=\"meta\">Chemical Engineering Journal 465, 142793 · <a href=\"https://doi.org/10.1016/j.cej.2023.142793\">doi:10.1016/j.cej.2023.142793</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Kekes et al., 2025 – Energy recovery in a small coffee plant.</strong> Modelled a plant in Athens, Greece, roasting 1,800 kg of green coffee a day with a natural-gas roaster and afterburner. Recirculating hot air from the afterburner lowered total energy per kg green coffee from 3,647.7 to 2,872.4 kJ, and greenhouse gas emissions by 25%.</p>\n<p class=\"meta\">Sustainability 17(3), 1334 · <a href=\"https://doi.org/10.3390/su17031334\">doi:10.3390/su17031334</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Vučković et al., 2016 – Exergy of an industrial batch roaster.</strong> An exergy and cost analysis of a gas-fired 300 kg batch roaster with afterburner, partly from on-site measurements. The overall exergy efficiency was 33.26%, exhaust gases were the largest single loss, and the authors estimate a heat recovery potential of 1.1 MW for large roasters.</p>\n<p class=\"meta\">Thermal Science 20 (Suppl. 5), S1271–S1283 · <a href=\"https://doi.org/10.2298/TSCI16S5271V\">doi:10.2298/TSCI16S5271V</a></p>\n</div>\n\n<div class=\"study\">\n<p><strong>Pantaleo et al., 2017 – Power from intermittent roaster heat.</strong> A techno-economic case study of a 500 kg/h batch drum plant with partial hot gas recycling and afterburner, assuming 1.5 MJ of natural gas per kg green coffee. It assessed organic Rankine cycle and micro gas turbine units for exhaust heat that arrives in short pulses.</p>\n<p class=\"meta\">Energy Procedia 129, 575–582 · <a href=\"https://doi.org/10.1016/j.egypro.2017.09.209\">doi:10.1016/j.egypro.2017.09.209</a></p>\n</div>"
}